Feasibility and long-term safety of elective Impella-assisted high-risk percutaneous coronary intervention: a pilot two-centre study

被引:50
作者
Burzotta, Francesco [2 ]
Paloscia, Leonardo [1 ]
Trani, Carlo [2 ]
Mascellanti, Marco [1 ]
Mongiardo, Rocco [2 ]
Materazzo, Guido [1 ]
Niccoli, Giampaolo [2 ]
Di Marco, Massimo [1 ]
Leone, Antonio Maria [2 ]
Porto, Italo [2 ]
Mazzari, Mario Attilio [2 ]
Rebuzzi, Antonio Giuseppe [2 ]
Schiavoni, Giovanni [2 ]
Crea, Filippo [2 ]
机构
[1] Spirito Santo Hosp, Div Cardiol, Pescara, Italy
[2] Univ Cattolica Sacro Cuore, Inst Cardiol, I-00168 Rome, Italy
关键词
ejection fraction; high-risk percutaneous coronary intervention; percutaneous ventricular assist device;
D O I
10.2459/JCM.0b013e3282f9abe7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective We evaluated the acute and long-term results of the use of a new intracardiac microaxial pump, the Impella Recover LP 2.5, during elective high-risk percutaneous coronary interventions in a two-centre registry. Methods Ten consecutive patients with poor left ventricular function and multivessel or left main coronary artery disease were considered at high risk of haemodynamic compromise and underwent percutaneous coronary interventions with preintervention Impella implantation. Procedural complications, 30-day and 12-month clinical outcome were recorded. Left ventricular ejection fraction was assessed by echocardiography before procedure and after at least 6 months. Results The Impella was implanted before percutaneous coronary interventions by femoral approach and percutaneous coronary interventions were successfully performed (by contra lateral femoral or radial approach) in all cases. After percutaneous coronary intervention, Impella was removed in all patients, and haemostasis was obtained by prolonged manual compression or by double suture device preimplantation technique. No access-site complication was observed and no patient required transfusions. One patient died after Impella removal due to acute stent thrombosis. The other patients had an uncomplicated in-hospital course and were discharged within 5 days. At 1-year follow-up, no patient died nor suffered acute myocardial infarction, whereas two patients underwent re-percutaneous coronary intervention. Left ventricular ejection fraction at follow-up increased significantly in this study population (from 31 +/- 7% to 41% +/- 13%, P = 0.02). Conclusion Our results support the feasibility and safety of Impella-assisted percutaneous coronary intervention in high-risk patients. Prospective randomized trials are needed to test the clinical impact of such an innovative approach.
引用
收藏
页码:1004 / 1010
页数:7
相关论文
共 13 条
[1]   PREDICTION OF RISK FOR HEMODYNAMIC COMPROMISE DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
BERGELSON, BA ;
JACOBS, AK ;
CUPPLES, LA ;
RUOCCO, NA ;
KYLLER, MG ;
RYAN, TJ ;
FAXON, DP .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (20) :1540-1545
[2]   Elective versus provisional intra-aortic balloon pumping in high-risk percutaneous transluminal coronary angioplasty [J].
Briguori, C ;
Sarais, C ;
Pagnotta, P ;
Airoldi, F ;
Liistro, F ;
Sgura, F ;
Spanos, V ;
Carlino, M ;
Montorfano, M ;
Di Mario, C ;
Colombo, A .
AMERICAN HEART JOURNAL, 2003, 145 (04) :700-707
[3]   Elective versus provisional intraaortic balloon pumping in unprotected left main stenting [J].
Briguori, Carlo ;
Airoldi, Flavio ;
Chieffo, Alaide ;
Montorfano, Matteo ;
Carlino, Mauro ;
Sangiorgi, Giuseppe Massimo ;
Morici, Nuccia ;
Michev, Iassen ;
Iakovou, Ioannis ;
Biondi-Zoccai, Giuseppe ;
Colombo, Antonio .
AMERICAN HEART JOURNAL, 2006, 152 (03) :565-572
[4]   Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5 [J].
Henriques, JPS ;
Remmelink, M ;
Baan, J ;
van der Schaaf, RJ ;
Vis, MM ;
Koch, KT ;
Scholten, EW ;
de Mol, BAJM ;
Tijssen, JGP ;
Piek, JJ ;
de Winter, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (07) :990-992
[5]  
Hopkins James, 2006, J Invasive Cardiol, V18, P97
[6]   Left ventricular support by catheter-mounted axial flow pump reduces infarct size [J].
Meyns, B ;
Stolinski, J ;
Leunens, V ;
Verbeken, E ;
Flameng, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (07) :1087-1095
[7]   COUNTERPULSATION - HISTORICAL BACKGROUND, TECHNICAL IMPROVEMENTS, HEMODYNAMIC AND METABOLIC EFFECTS [J].
NANAS, JN ;
MOULOPOULOS, SD .
CARDIOLOGY, 1994, 84 (03) :156-167
[8]   A case of fatal stent thrombosis after Carbostent implantation: Is clopidogrel alone antiplatelet therapy a safe alternative to aspirin alone antiplatelet therapy? [J].
Niccoli, Giampaolo ;
Siviglia, Massimo ;
De Vita, Maria ;
Altamura, Luca ;
Fusco, Beatrice ;
Leone, Antonio Maria ;
Ferrante, Giuseppe ;
Rebuzzi, Antonio G. ;
Crea, Filippo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 114 (02) :279-281
[9]   High-risk percutaneous coronary intervention using the intracardiac microaxial pump 'Impella Recover' [J].
Ramondo, Angelo ;
Napodano, Massimo ;
Tarantini, Giuseppe ;
Calzolari, Diego ;
Nalli, Chiara ;
Cacciavillani, Luisa ;
Iliceto, Sabino .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (02) :149-152
[10]   Miniature intracardiac assist device provides more effective cardiac unloading and circulatory support during severe left heart failure than intraaortic balloon pumping [J].
Reesink, KD ;
Dekker, AL ;
van Ommen, V ;
Soemers, C ;
Geskes, GG ;
van der Veen, FH ;
Maessen, JG .
CHEST, 2004, 126 (03) :896-902