Model-based scatter correction for fully 3D PET

被引:245
作者
Ollinger, JM
机构
[1] Washington University, Neuro-Imaging Laboratory, Campus Box 8225, St Louis, MO 63110
关键词
D O I
10.1088/0031-9155/41/1/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method is presented that directly calculates the mean number of scattered coincidences in data acquired with fully 3D positron emission tomography (PET). This method uses a transmission scan, an emission scan, the physics of Compton scatter, and a mathematical model of the scanner in a forward calculation of the number of events for which one photon has undergone a single Compton interaction. The distribution of events for which multiple Compton interactions have occurred is modelled as a linear transformation of the single-scatter distribution. Computational efficiency is achieved by sampling at rates no higher than those required by the scatter distribution and by implementing the algorithm using look-up tables. Evaluation studies in phantoms with large scatter fractions show that the method yields images with quantitative accuracy equivalent to that of slice-collimated PET in clinically useful times.
引用
收藏
页码:153 / 176
页数:24
相关论文
共 37 条
[1]  
BAILEY DL, 1993, PHYS MED BIOL, V39, P411
[2]   OBJECT SHAPE DEPENDENT SCATTER SIMULATIONS FOR PET [J].
BARNEY, JS ;
ROGERS, JG ;
HARROP, R ;
HOVERATH, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :719-725
[3]  
BENDRIEM B, 1994, 1993 IEEE MED IM C R, V3, P1779
[4]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[6]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[7]   EFFECTS OF SCATTER ON MODEL PARAMETER ESTIMATES IN 3D PET STUDIES OF THE HUMAN BRAIN [J].
CHERRY, SR ;
HUANG, SC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1174-1179
[8]  
CHERRY SR, 1993, J NUCL MED, V34, P671
[9]   3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :655-668
[10]   IMPLEMENTATION OF 3-DIMENSIONAL IMAGE-RECONSTRUCTION FOR MULTIRING POSITRON TOMOGRAPHS [J].
DEFRISE, M ;
TOWNSEND, D ;
GEISSBUHLER, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1361-1372