The Insall-Burstein total knee replacement in osteoarthritis - A 10-year minimum follow-up

被引:94
作者
Aglietti, P [1 ]
Buzzi, R [1 ]
De Felice, R [1 ]
Giron, F [1 ]
机构
[1] Univ Florence, Orthopaed Clin 1, I-50139 Florence, Italy
关键词
total knee arthroplasty; posterior stabilized prosthesis; long-term results; osteolysis;
D O I
10.1016/S0883-5403(99)90077-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A total of 99 Insall-Burstein posterior stabilized (IBPS) knee replacements were implanted in 86 osteoarthritic patients. We reviewed 60 knees with a 10- to 15-year follow-up. Using the Knee Society score, 35 knees (58%) were excellent, 15 (25%) good, 4 (7%) fair, and 6 (10%) poor. Flexion at follow-up was 106 degrees on average. Moderate patellofemoral crepitation was present in 5 knees (9%), and 1 knee required excision of a synovial nodule proximal to the patella. Radiographic analysis showed 5 osteolytic lesions (8%) around well-fixed tibial and femoral components and minimal (1 mm) narrowing of the medial pelyethylene thickness in 7 knees (12%). There were 6 (10%) failures requiring reoperation because of aseptic loosening (4 knees), deep infection (1 knee), and recurrent patellar dislocation (1 knee). Survivorship analysis using revision as the endpoint showed a cumulative success rate of 92% at 10 years. In this study, the IBPS knee has shown good long-term results with low rates of aseptic loosening and no failures attributable to polyethylene wear.
引用
收藏
页码:560 / 565
页数:6
相关论文
共 27 条
[1]   POSTERIORLY STABILIZED TOTAL-CONDYLAR KNEE REPLACEMENT - 3 TO 8 YEARS FOLLOW-UP OF 85 KNEES [J].
AGLIETTI, P ;
BUZZI, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (02) :211-216
[2]  
Aglietti P, 1989, J Arthroplasty, V4, P1, DOI 10.1016/S0883-5403(89)80046-4
[3]  
Aglietti P, 1988, J Arthroplasty, V3, P17, DOI 10.1016/S0883-5403(88)80049-4
[4]   INSALL-BURSTEIN POSTERIOR-STABILIZED KNEE PROSTHESIS IN RHEUMATOID-ARTHRITIS [J].
AGLIETTI, P ;
BUZZI, R ;
SEGONI, F ;
ZACCHEROTTI, G .
JOURNAL OF ARTHROPLASTY, 1995, 10 (02) :217-225
[5]  
ANDRIACCHI TP, 1988, J ARTHROPLASTY S, V3, P13
[6]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[7]   THE POSTERIOR STABILIZED TOTAL KNEE PROSTHESIS - ASSESSMENT OF POLYETHYLENE DAMAGE AND OSTEOLYSIS AFTER A 10-YEAR-MINIMUM FOLLOW-UP [J].
COLIZZA, WA ;
INSALL, JN ;
SCUDERI, GR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) :1713-1720
[8]   POLYETHYLENE WEAR OF METAL-BACKED TIBIAL COMPONENTS IN TOTAL AND UNICOMPARTMENTAL KNEE PROSTHESES [J].
ENGH, GA ;
DWYER, KA ;
HANES, CK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :9-17
[9]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[10]  
FENG EL, 1994, CLIN ORTHOP RELAT R, P60