Prevalence and predictors of electrical storm in patients with implantable cardioverter-defibrillator

被引:85
作者
Arya, A [1 ]
Haghjoo, M [1 ]
Dehghani, MR [1 ]
Fazelifar, AF [1 ]
Nikoo, MH [1 ]
Bagherzadeh, A [1 ]
Sadr-Ameli, MA [1 ]
机构
[1] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Dept Pacemaker & Electrophysiol, Tehran, Iran
关键词
D O I
10.1016/j.amjcard.2005.08.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Identifying predictors of electrical storm in patients with implantable cardioverter-defibrillators (ICDs) could help identify those at risk and reduce the incidence of this emergency situation, which has a detrimental effect on mortality and morbidity in patients with ICDs. This retrospective study sought to determine the prevalence and predictors of electrical storm in patients with ICDs. One hundred sixty-two patients (126 men; mean age 58 +/- 13 years) who received ICDs from January 2001 to January 2005 were included in the study. Clinical, electrocardiographic, and ICD stored data and electrograms were collected and analyzed. Twenty-two patients (14%) developed electrical storm during a mean follow-up of 14.3 +/- 10 months. Using Cox multiple regression analysis, it was found that an ejection fraction < 25% (p = 0.007), QRS width >= 120 ms (p = 0.002), and a lack of adjunctive angiotensin-converting enzyme inhibitor and P-blocker therapy (both p < 0.001) were correlated with a greater probability of electrical storm. Adjunctive amiodarone and digoxin therapy, indication of ICD implantation, and age were not correlated with the occurrence of electrical storm during follow-up (all p = NS). In conclusion, electrical storm is not uncommon in patients with ICDs. Optimum medical therapy with beta blockers and angiotensin-converting enzyme inhibitors could reduce the occurrence of electrical storm, and this especially should be considered in those at greater risk for this complication (i.e., those with left ventricular ejection fractions < 25% and QRS widths >= 120ms). (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 19 条
  • [1] Successful catheter ablation of electrical storm after myocardial infarction
    Bänsch, D
    Oyang, F
    Antz, M
    Arentz, T
    Weber, R
    Val-Mejias, JE
    Ernst, S
    Kuck, KH
    [J]. CIRCULATION, 2003, 108 (24) : 3011 - 3016
  • [2] Relation of ejection fraction and inducible ventricular tachycardia to mode of death in patients with coronary artery disease - An analysis of patients enrolled in the Multicenter Unsustained Tachycardia Trial
    Buxton, AE
    Lee, KL
    Hafley, GE
    Wyse, DG
    Fisher, JD
    Lehmann, MH
    Pires, LA
    Gold, MR
    Packer, DL
    Josephson, ME
    Prystowsky, EN
    Talajic, MR
    [J]. CIRCULATION, 2002, 106 (19) : 2466 - 2472
  • [3] Electrical storm in patients with transvenous implantable cardioverter-defibrillators - Incidence, management and prognostic implications
    Credner, SC
    Klingenheben, T
    Mauss, O
    Sticherling, C
    Hohnloser, SH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) : 1909 - 1915
  • [4] Lipid lowering drugs and recurrences of life-threatening ventricular arrhythmias in high-risk patients
    De Sutter, J
    Tavernier, R
    De Buyzere, M
    Jordaens, L
    De Backer, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 766 - 772
  • [5] A comparative analysis of the results from 4 trials of β-blocker therapy for heart failure:: BEST, CIBIS-II, MERIT-HF, and COPERNICUS
    Domanski, MJ
    Krause-Steinrauf, H
    Massie, BM
    Deedwania, P
    Follmann, D
    Kovar, D
    Murray, D
    Oren, R
    Rosenberg, Y
    Young, J
    Zile, M
    Eichhorn, E
    [J]. JOURNAL OF CARDIAC FAILURE, 2003, 9 (05) : 354 - 363
  • [6] Placebo-controlled, randomized clinical trial of azimilide for prevention of ventricular tachyarrhythmias in patients with an implantable cardioverter defibrillator
    Dorian, P
    Borggrefe, M
    Al-Khalidi, HR
    Hohnloser, SH
    Brum, JM
    Tatla, DS
    Brachmann, J
    Myerburg, RJ
    Cannom, DS
    van der Laan, M
    Holroyde, MJ
    Singer, I
    [J]. CIRCULATION, 2004, 110 (24) : 3646 - 3654
  • [7] Clinical significance of consecutive shocks in patients with left ventricular dysfunction treated with implantable cardioverter defibrillators
    Endoh, Y
    Ohnishi, S
    Kasanuki, H
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 187 - 191
  • [8] Exner DV, 2001, CIRCULATION, V103, P2066
  • [9] Electrical storm is an independent predictor of adverse long-term outcome in the era of implantable defibrittator therapy
    Gatzoulis, KA
    Andrikopoulos, GK
    Apostolopoulos, T
    Sotiropoulos, E
    Zervopoulos, G
    Antoniou, J
    Brili, S
    Stefanadis, CI
    [J]. EUROPACE, 2005, 7 (02): : 184 - 192
  • [10] Is electrical storm in ICD patients the sign of a dying heart? Outcome of patients with clusters of ventricular tachyarrhythmias
    Greene, M
    Newman, D
    Geist, M
    Paquette, M
    Heng, D
    Dorian, P
    [J]. EUROPACE, 2000, 2 (03): : 263 - 269