Detection of time-resolved photoionization currents from pesticide-contaminated vegetation

被引:8
作者
Kadosh, M [1 ]
Gridin, VV [1 ]
Schechter, I [1 ]
机构
[1] Technion Israel Inst Technol, Dept Chem, IL-32000 Haifa, Israel
关键词
D O I
10.1560/19QM-F8YJ-UN3F-KHUQ
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Multiphoton-ionization fast-conductance (MPI-FC) was directly applied for detection of photoionization currents originated from pesticide traces irradiated by UV-laser. The principal methodology required for direct screening of pesticide traces deposited on various vegetational specimens was addressed. This approach was exemplified with 1,2,3,4,5,6-hexachlorocyclohexane and 3-amino-1,2,4-triazole, which are frequently found in agriculture-related industries. The range of pesticide concentrations covered was from 0.001 ng/mL to 1 mg/mL, and all measurements were carried out under ambient conditions. Our target vegetation substrates were sampled from the outdoors: grass, plant, and/or tree leaves. Neither material purification nor laborious extraction routines were utilized; thus employing MPI-FC for in situ/on-line monitoring of pesticide-contaminated vegetation is feasible.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 43 条
[41]  
Weissenbacher N, 1997, J MOL STRUCT, V410, P539
[42]   SUBMICROLITER TRANSPARENT CELL FOR LASER MULTIPHOTON IONIZATION DETECTION IN SOLUTION [J].
YAMADA, S .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1894-1897
[43]  
YOO LJ, 1995, P WAT QUAL TECHN C 1, P177