Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation

被引:464
作者
Hanley, J
Debois, MM
Mah, D
Mageras, GS
Raben, A
Rosenzweig, K
Mychalczak, B
Schwartz, LH
Gloeggler, PJ
Lutz, W
Ling, CC
Leibel, SA
Fuks, Z
Kutcher, GJ
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
[4] Mem Sloan Kettering Canc Ctr, Dept Pulm, New York, NY 10021 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 45卷 / 03期
关键词
lung carcinoma; spirometry; respiration gating; breath-hold;
D O I
10.1016/S0360-3016(99)00154-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose/Objective: This study evaluates the dosimetric benefits and feasibility of a deep inspiration breath-hold (DIBH) technique in the treatment of lung tumors. The technique has two distinct features-deep inspiration, which reduces lung density, and breath-hold, which immobilizes lung tumors, thereby allowing for reduced margins. Both of these properties can potentially reduce the amount of normal lung tissue in the high-dose region, thus reducing morbidity and improving the possibility of dose escalation. Methods and Materials: Five patients treated for non-small cell lung carcinoma (Stage IIA-IIIB) received computed tomography (CT) scans under 4 respiration conditions: free-breathing, DIBH, shallow inspiration breath-hold, and shallow expiration breath-hold. The free-breathing and DIBH scans were used to generate 3-dimensional conformal treatment plans for comparison, while the shallow inspiration and expiration scans determined the extent of tumor motion under free-breathing conditions. To acquire the breath-hold scans, the patients are brought to reproducible respiration levels using spirometry, and for DIBH, modified slow vital capacity maneuvers. Planning target volumes (PTVs) for free-breathing plans included a margin for setup error (0.75 cm) plus a margin equal to the extent of tumor motion due to respiration (1-2 cm). Planning target volumes for DIBH plans included the same margin for setup error, with a reduced margin for residual uncertainty in tumor position (0.20.5 cm) as determined from repeat fluoroscopic movies. To simulate the effects of respiration-gated treatments and estimate the role of target immobilization alone (i.e., without the benefit of reduced lung density), a third plan is generated from the free-breathing scan using a PTV with the same margins as for DIBH plans. Results: The treatment plan comparison suggests that, on average, the DIBH technique can reduce the volume of lung receiving more than 25 Gy by 30% compared to free-breathing plans, while respiration gating can reduce the volume by 18%. The DIBH maneuver was found to be highly reproducible, with intra breath-hold reproducibility of 1.0 (+/- 0.9) mm and inter breath-hold reproducibility of 2.5 (+/- 1.6) mm, as determined from diaphragm position. Patients were able to perform 10-13 breath-holds in one session, with a comfortable breath-hold duration of 12-16 s. Conclusion: Patients tolerate DIBH maneuvers well and can perform them in a highly reproducible fashion. Compared to conventional free-breathing treatment, the DIBH technique benefits from reduced margins, as a result of the suppressed target motion, as well as a decreased lung density; both contribute to moving normal lung tissue out of the high-dose region. Because less normal lung tissue is irradiated to high dose, the possibility for dose escalation is significantly improved. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 22 条
[1]  
*AM THOR SOC, 1994, AJRCCM, P152
[2]   3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER [J].
ARMSTRONG, JG ;
BURMAN, C ;
LEIBEL, S ;
FONTENLA, D ;
KUTCHER, G ;
ZELEFSKY, M ;
FUKS, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04) :685-689
[3]  
DEBOIS MM, 1996, MED PHYS, V23, P1082
[4]   PITFALLS IN THE USE OF HIGH-ENERGY X-RAYS TO TREAT TUMORS IN THE LUNG [J].
EKSTRAND, KE ;
BARNES, WH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :249-252
[5]   ACCURACY OF LUNG DOSE CALCULATIONS FOR LARGE-FIELD IRRADIATION WITH 6-MV X-RAYS [J].
ELKHATIB, E ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1986, 13 (01) :111-116
[6]   TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION [J].
EMAMI, B ;
LYMAN, J ;
BROWN, A ;
COIA, L ;
GOITEIN, M ;
MUNZENRIDER, JE ;
SHANK, B ;
SOLIN, LJ ;
WESSON, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :109-122
[7]  
FROHLICH H, 1985, RADIOLOGY, V156, P235
[8]   A software toes for the quantitative evaluation of 3D dose calculation algorithms [J].
Harms, WB ;
Low, DA ;
Wong, JW ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (10) :1830-1836
[9]   MEASUREMENT OF PULMONARY PARENCHYMAL ATTENUATION - USE OF SPIROMETRIC GATING WITH QUANTITATIVE CT [J].
KALENDER, WA ;
RIENMULLER, R ;
SEISSLER, W ;
BEHR, J ;
WELKE, M ;
FICHTE, H .
RADIOLOGY, 1990, 175 (01) :265-268
[10]   THE INFLUENCE OF AIR CAVITIES ON INTERFACE DOSES FOR PHOTON BEAMS [J].
KLEIN, EE ;
CHIN, LM ;
RICE, RK ;
MIJNHEER, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :419-427