Saline volume in transvesical intra-abdominal pressure measurement: enough is enough

被引:83
作者
De Waele, J [1 ]
Pletinckx, P [1 ]
Blot, S [1 ]
Hoste, E [1 ]
机构
[1] Ghent Univ Hosp, Intens Care Unit 1K12 C, B-9000 Ghent, Belgium
关键词
intra-abdominal pressure; intra-abdominal hypertension; abdominal compartment syndrome; surgery; trauma; critically ill patients; intensive care;
D O I
10.1007/s00134-005-0062-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The objective was to determine the minimum volume of instillation fluid for intra-abdominal pressure (IAP) measurement, and to evaluate the effect of instillation volume on transvesically measured IAP. Design: Prospective cohort study Setting: Twenty-two-bed surgical ICU of the Ghent University Hospital Patients and participants: Twenty patients at risk of intra-abdominal hypertension (IAH). Interventions: Transvesical IAP measurement using volumes from 10 to 100 ml. Minimal volume at which an IAP was measured was recorded (IAP(min)), as well as IAP at 50 and 100 ml of instillation volume (IAP(50) and IAP(100)). The percentage difference for IAP(50) and IAP(100) was calculated. Measurements and results: The minimal volume for IAP measurement was 10 ml in all patients. Mean IAPmin was 12.8 mmHg (+/- 4.9), mean IAP(50) 15 mmHg (+/- 4.5) and mean IAP(100) 17.1 mmHg (+/- 4.7). The mean percentage difference for IAP50 was 21% (+/- 17%), and 40% (+/- 29%) for IAP(100). Twelve patients were categorised as suffering from IAH when 10 ml of saline was used for IAP measurement, increasing to 15 and 17 patients respectively when using 50 and 100 ml. In patients with IAH, there was a significant correlation between the duration of bladder drainage and percentage difference for IAP(100) (Pearson correlation coefficient 0.60, p = 0.03). Conclusions: Using 50 or 100 ml of saline for IAP measurement in critically ill patients results in higher IAP values compared with the use of 10 ml, and possibly, in overestimation of the incidence of intra-abdominal hypertension.
引用
收藏
页码:455 / 459
页数:5
相关论文
共 14 条
[1]   Continuous intra-abdominal pressure measurement technique [J].
Balogh, Z ;
Jones, F ;
D'Amours, S ;
Parr, M ;
Sugrue, M .
AMERICAN JOURNAL OF SURGERY, 2004, 188 (06) :679-683
[2]   The abdominal compartment syndrome [J].
Burch, JM ;
Moore, EE ;
Moore, FA ;
Franciose, R .
SURGICAL CLINICS OF NORTH AMERICA, 1996, 76 (04) :833-+
[3]   Intraabdominal pressure: A revised method for measurement (vol 186, pg 368, 1998) [J].
Cheatham, ML ;
Safcsak, K .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (05) :594-595
[4]   Abdominal perfusion pressure: A superior parameter in the assessment of intra-abdominal hypertension [J].
Cheatham, ML ;
White, MW ;
Sagraves, SG ;
Johnson, JL ;
Block, EFJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 49 (04) :621-626
[5]   Estimation of intra-abdominal pressure by bladder pressure measurement: Validity and methodology [J].
Fusco, MA ;
Martin, RS ;
Chang, MC .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (02) :297-302
[6]   BLADDER HYPOCOMPLIANCE IN THE SPINAL-CORD INJURY POPULATION [J].
HACKLER, RH ;
HALL, MK ;
ZAMPIERI, TA .
JOURNAL OF UROLOGY, 1989, 141 (06) :1390-1393
[7]   DETERMINATION OF INTRA-ABDOMINAL PRESSURE USING A TRANS-URETHRAL BLADDER CATHETER - CLINICAL VALIDATION OF THE TECHNIQUE [J].
IBERTI, TJ ;
LIEBER, CE ;
BENJAMIN, E .
ANESTHESIOLOGY, 1989, 70 (01) :47-50
[8]   Can we use the bladder to estimate intra-abdominal pressure? [J].
Johna, S .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 51 (06) :1218-1218
[9]   Abdominal compartment syndrome: does intra-cystic pressure reflect actual intra-abdominal pressure? A prospective study in surgical patients [J].
Johna, S ;
Taylor, E ;
Brown, C ;
Zimmerman, G .
CRITICAL CARE, 1999, 3 (06) :135-138
[10]   THE MEASUREMENT OF INTRA-ABDOMINAL PRESSURE AS A CRITERION FOR ABDOMINAL RE-EXPLORATION [J].
KRON, IL ;
HARMAN, PK ;
NOLAN, SP .
ANNALS OF SURGERY, 1984, 199 (01) :28-30