Cam Lesion Femoral Osteoplasty: In Vitro Biomechanical Evaluation of Iatrogenic Femoral Cortical Notching and Risk of Neck Fracture

被引:25
作者
Wijdicks, Coen A. [1 ]
Balldin, B. Christian [1 ]
Jansson, Kyle S. [1 ]
Stull, Justin D. [1 ]
LaPrade, Robert F. [2 ]
Philippon, Marc J. [2 ]
机构
[1] Steadman Philippon Res Inst, Dept Biomed Engn, Vail, CO 81657 USA
[2] Steadman Clin, Vail, CO 81657 USA
关键词
FEMOROACETABULAR IMPINGEMENT; HIP; PREVALENCE; ARTHROSCOPY; JUNCTION; ATHLETE; ALPHA; FEMUR; SIZE;
D O I
10.1016/j.arthro.2013.06.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Purpose: To investigate the effect of femoral cortical notching at different depths on the peak compressive load and energy required to cause a femoral neck fracture in composite femurs. Methods: Thirty fourth-generation composite femurs were divided into 5 groups: (1) intact with an inherent alpha angle of 61 degrees, (2) resection of inherent cam lesion by reducing the alpha angle from 61 degrees to 45 degrees, (3) cam resection and cortical notching of a 5.5-mm spherical diameter by 2.00-mm (grade I) depth, (4) cam resection with cortical notching of 4.00-mm (grade II) depth, and (5) cam resection with cortical notching of 6.00-mm (grade III) depth. The specimens were loaded in the position of midstance during gait and tested until failure using a dynamic tensile testing machine at a rate of 6 mm/min. Results: Grade II and grade III cortical notching depths with cam resections resulted in a significant decrease in the ultimate load to failure and energy (P < .05) compared with the intact state. The grade II and grade III cortical notching groups with cam resection failed at a significantly lower ultimate load and with significantly lower energy when compared with the cam resection group alone. Conclusions: The findings of this study demonstrated significant decreases in ultimate load and energy to failure between the intact group and the grade II and grade III femoral cortical notching groups with cam resection. Clinical Relevance: Iatrogenic cortical notching may lead to an increased risk of postsurgical complications, specifically femoral neck fracture. Thus, surgical intervention for a cam lesion femoral osteoplasty should strive for precision, especially around the femoral neck.
引用
收藏
页码:1608 / 1614
页数:7
相关论文
共 32 条
[1]
Femoral Neck Fracture After Arthroscopic Management of Femoroacetabular Impingement [J].
Ayeni, Olufemi R. ;
Bedi, Asheesh ;
Lorich, Dean G. ;
Kelly, Bryan T. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (09) :893-893
[2]
Femoroacetabular Impingement [J].
Bedi, Asheesh ;
Kelly, Bryan T. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (01) :82-92
[3]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[4]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[5]
BLAIR B, 1994, CLIN ORTHOP RELAT R, V306, P256
[6]
Ultrasound for the evaluation of femoroacetabular impingement of the cam type. Diagnostic performance of qualitative criteria and alpha angle measurements [J].
Buck, Florian M. ;
Hodler, Juerg ;
Zanetti, Marco ;
Dora, Claudio ;
Pfirrmann, Christian W. A. .
EUROPEAN RADIOLOGY, 2011, 21 (01) :167-175
[7]
Cohen J, 1977, STAT POWER ANAL BEHA, P274
[8]
Colvin AC, 2012, J BONE JOINT SURG AM, V94A, P227, DOI [10.2106/JBJS.J.00739, 10.2106/JBJS.J.01886]
[9]
Davis ET, 2012, J BIOMECH ENG, V131
[10]
G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences [J].
Faul, Franz ;
Erdfelder, Edgar ;
Lang, Albert-Georg ;
Buchner, Axel .
BEHAVIOR RESEARCH METHODS, 2007, 39 (02) :175-191