Measurement of glomerular filtration rate and effective renal plasma flow in the conscious beagle dog by single intravenous bolus of iohexol and p-aminohippuric acid

被引:45
作者
Laroute, V [1 ]
Lefebvre, HP [1 ]
Costes, G [1 ]
Toutain, PL [1 ]
机构
[1] Ecole Natl Vet Toulouse, INRA, Unite Associee Physiopathol & Toxicol Expt, F-31076 Toulouse, France
关键词
dog; effective renal plasma flow; glomerular filtration rate; high-performance liquid chromatography; iohexol; para-aminohippuric acid; pharmacokinetics;
D O I
10.1016/S1056-8719(99)00016-7
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The objective of this study was to validate a kinetic approach for the simultaneous measurement of glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) in the dog. Six healthy male Beagle dogs were randomly assigned in a three-period cross-over study of intravenous bolus administration of iohexol (64.7 mg/kg). PAH (10 mg/kg), and an iohexol/PAH mixture. PAH and iohexol were determined simultaneously by a validated high-performance liquid chromatographic method. The iohexol and PAH data obtained after intravenous administration were analyzed using noncompartmental and bicompartmental approaches. A simplified iohexol plasma clearance was also calculated from the terminal elimination phase of the plasma iohexol concentrations versus time profile. The total plasma clearance values for PAH and exo-iohexol were 13 +/- 2.3 mL/kg/min and 2.9 +/- 0.3 mL/kg/min, respectively. No significant (or biologically relevant) effect of coadministration of PAH and iohexol was observed on the pharmacokinetic parameters of either drug. The calculation of simplified plasma clearance led to an overestimation of the true plasma clearance. In conclusion, GFR and ERPF can easily and rapidly be measured in the dog by this approach which is relatively noninvasive. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 32 条
[2]  
Brown SA, 1996, AM J VET RES, V57, P105
[3]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[4]   Sinistrin clearance for determination of glomerular filtration rate: A reappraisal of various approaches using a new analytical method [J].
Buclin, T ;
PechereBertschi, A ;
Sechaud, R ;
Decosterd, LA ;
Munafo, A ;
Burnier, M ;
Biollaz, J .
JOURNAL OF CLINICAL PHARMACOLOGY, 1997, 37 (08) :679-692
[5]   High-performance liquid chromatography of the renal blood flow marker p-aminohippuric acid (PAH) and its metabolite N-acetyl PAH improves PAH clearance measurements [J].
Decosterd, LA ;
Karagiannis, A ;
Roulet, JM ;
Bélaz, N ;
Appenzeller, M ;
Buclin, T ;
Vogel, P ;
Biollaz, J .
JOURNAL OF CHROMATOGRAPHY B, 1997, 703 (1-2) :25-36
[6]   PHARMACOKINETICS OF IOHEXOL, A NEW NONIONIC RADIOCONTRAST AGENT, IN HUMANS [J].
EDELSON, J ;
SHAW, D ;
PALACE, G .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (07) :993-995
[7]   Chronic renal blood flow measurement in dogs by transit-time ultrasound flowmetry [J].
Evans, RG ;
Stevenson, KM ;
Malpas, SC ;
Fitzgerald, SM ;
Shweta, A ;
Tomoda, F ;
Anderson, WP .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1997, 38 (01) :33-39
[8]  
FRENNBY B, 1995, CLIN NEPHROL, V43, P35
[9]  
Gaspari F, 1998, J AM SOC NEPHROL, V9, P310
[10]  
GASPARI F, 1997, KIDNEY INT S, V63, pS151