Sensitive DNA electrical detection based on interdigitated Al/Al2O3 microelectrodes

被引:57
作者
Moreno-Hagelsieb, L
Lobert, PE
Pampin, R
Bourgeois, D
Remacle, J
Flandre, D
机构
[1] Univ Catholique Louvain, DICE, Microelect Lab, Res Ctr Micro & Nanoscop Mat & Elect Devices, B-1348 Louvain, Belgium
[2] Fac Univ Notre Dame Paix, Lab Biochim & Biol Cellulaire, B-5000 Namur, Belgium
[3] Fac Polytech Mons, Serv Electron, Mons, Belgium
关键词
sensitive DNA; electrical detection; microelectrodes;
D O I
10.1016/j.snb.2003.10.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection of DNA by electrical based methods still faces the challenge of the low amounts of genetic material to be analyzed in order to make the assay useful for biological applications. In this work we present the possibility of detecting DNA strands by measuring a change of capacitance between interdigitated electrodes, of 1, 2 and 3 mum widths and spacing, made of aluminum fingers, coated with a thin alumina layer and constructed over an oxidized silicon wafer, reducing the non-specific precipitation of silver that occurs when using noble metal electrodes like gold. Labeling of DNA was performed by incorporation of biotinylated nucleotides and reaction with anti-biotin antibodies coupled to gold nanoparticles, whose size was increased by silver crystal precipitation. We observed a change in capacitance by a factor of at least two, using DNA solutions down to 0.2 nM, spotted on the electrodes. This method of detection thus appears compatible with the requirements of microarray technology and paves the way for further use in biological applications. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 274
页数:6
相关论文
共 17 条
  • [1] Colorimetric silver detection of DNA microarrays
    Alexandre, I
    Hamels, S
    Dufour, S
    Collet, J
    Zammatteo, N
    De Longueville, F
    Gala, JL
    Remacle, J
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 295 (01) : 1 - 8
  • [2] A DNA diagnostic biosensor: development, characterisation and performance
    Berney, H
    West, J
    Haefele, E
    Alderman, J
    Lane, W
    Collins, JK
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) : 100 - 108
  • [3] GUIDUCCI C, 2002, BIOSENSOR DIRECT DET
  • [4] Consensus PCR and microarray for diagnosis of the genus Staphylococcus, species, and methicillin resistance
    Hamels, S
    Gala, JL
    Dufour, S
    Vannuffel, P
    Zammatteo, N
    Remacle, J
    [J]. BIOTECHNIQUES, 2001, 31 (06) : 1364 - +
  • [5] HOFMANN F, 2002, PASSIVE DNA SENS0R G
  • [6] LILLIS B, 2002, 16 EUR C SOL STAT TR
  • [7] Immobilization of DNA on CMOS compatible materials
    Lobert, PE
    Bourgeois, D
    Pampin, R
    Akheyar, A
    Hagelsieb, LM
    Flandre, D
    Remacle, J
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (1-2) : 90 - 97
  • [8] Planar interdigitated electrolyte-conductivity sensors on an insulating substrate covered with Ta2O5
    Olthuis, W
    Sprenkels, AJ
    Bomer, JG
    Bergveld, P
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 43 (1-3) : 211 - 216
  • [9] Park SJ, 2002, SCIENCE, V295, P1503, DOI 10.1126/science.1067003
  • [10] SCHYBERG C, 1996, THESIS I NATL SCI AP