Molecular imprinted polymers: Useful tools for pharmaceutical analysis

被引:20
作者
Baggiani, Claudio [1 ]
Anfossi, Laura [1 ]
Giovannoli, Cristina [1 ]
机构
[1] Univ Turin, Dipartimento Chim Analit, I-10125 Turin, Italy
关键词
molecular imprinting; chiral separation; solid phase extraction; libraries; high throughput screening; capillary electrochromatography; capillary electrophoresis;
D O I
10.2174/157341206777934662
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Molecular imprinted polymers are man-made materials with predetermined selectivity towards one or more analytes. They have been used as selective stationary phases in several analytical separative techniques. This review discusses the possible uses of imprinted polymers, with a particular emphasis on their use as high pressure and electrochromatographic stationary phases for resolution of optical enantiomers, materials for fast screening of libraries and selective solid-phase extraction for sample clean-up and preconcentration.
引用
收藏
页码:219 / 247
页数:29
相关论文
共 324 条
[1]   Enantioselective solid-phase extraction using Troger's base molecularly imprinted polymers [J].
Adbo, K ;
Nicholls, IA .
ANALYTICA CHIMICA ACTA, 2001, 435 (01) :115-120
[2]   Enantioselective troger's base synthetic receptors [J].
Adbo, K ;
Andersson, HS ;
Ankarloo, J ;
Karlsson, JG ;
Norell, MC ;
Olofsson, L ;
Svenson, J ;
Örtegren, U ;
Nicholls, IA .
BIOORGANIC CHEMISTRY, 1999, 27 (05) :363-371
[3]   Imprinted polymers: artificial molecular recognition materials with applications in synthesis and catalysis [J].
Alexander, C ;
Davidson, L ;
Hayes, W .
TETRAHEDRON, 2003, 59 (12) :2025-2057
[4]  
Allender CJ, 1997, CHIRALITY, V9, P233, DOI 10.1002/(SICI)1520-636X(1997)9:3<233::AID-CHIR5>3.0.CO
[5]  
2-G
[6]   PREPARATION OF AMINO-ACID ESTER-SELECTIVE CAVITIES FORMED BY NON-COVALENT IMPRINTING WITH A SUBSTRATE IN HIGHLY CROSS-LINKED POLYMERS [J].
ANDERSSON, L .
REACTIVE POLYMERS, 1988, 9 (01) :29-41
[7]   ENANTIOMERIC RESOLUTION OF AMINO-ACID DERIVATIVES ON MOLECULARLY IMPRINTED POLYMERS AS MONITORED BY POTENTIOMETRIC MEASUREMENTS [J].
ANDERSSON, LI ;
MIYABAYASHI, A ;
OSHANNESSY, DJ ;
MOSBACH, K .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (02) :323-331
[8]   MOLECULAR RECOGNITION IN SYNTHETIC-POLYMERS - PREPARATION OF CHIRAL STATIONARY PHASES BY MOLECULAR IMPRINTING OF AMINO-ACID AMIDES [J].
ANDERSSON, LI ;
OSHANNESSY, DJ ;
MOSBACH, K .
JOURNAL OF CHROMATOGRAPHY, 1990, 513 :167-179
[9]   Molecular imprinting for drug bioanalysis - A review on the application of imprinted polymers to solid-phase extraction and binding assay [J].
Andersson, LI .
JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01) :163-173
[10]   Development of a molecularly imprinted polymer based solid-phase extraction of local anaesthetics from human plasma [J].
Andersson, LI ;
Hardenborg, E ;
Sandberg-Ställ, M ;
Möller, K ;
Henriksson, J ;
Bramsby-Sjöström, I ;
Olsson, LI ;
Abdel-Rehim, M .
ANALYTICA CHIMICA ACTA, 2004, 526 (02) :147-154