A beamformer post-filter for cochlear implant noise reduction

被引:18
作者
Hersbach, Adam A. [1 ,3 ]
Grayden, David B. [1 ,2 ,4 ]
Fallon, James B. [2 ,5 ,6 ]
McDermott, Hugh J. [2 ,5 ,6 ]
机构
[1] Univ Melbourne, Dept Elect & Elect Engn, NeuroEngn Lab, Melbourne, Vic, Australia
[2] Bion Inst, East Melbourne, Australia
[3] Cochlear Ltd, East Melbourne, Australia
[4] Univ Melbourne, Ctr Neural Engn, Melbourne, Vic, Australia
[5] Univ Melbourne, Dept Otolaryngol, Melbourne, Vic, Australia
[6] Univ Melbourne, Dept Med Bion, Melbourne, Vic, Australia
关键词
DIRECTIONAL MICROPHONE; SPEECH RECOGNITION; BACKGROUND-NOISE; PERCEPTION; PROCESSOR;
D O I
10.1121/1.4794391
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Cochlear implant users have limited ability to understand speech in noisy conditions. Signal processing methods to address this issue that use multiple microphones typically use beamforming to perform noise reduction. However, the effectiveness of the beamformer is diminished as the number of interfering noises increases and the acoustic environment becomes more diffuse. A multi-microphone noise reduction algorithm that aims to address this issue is presented in this study. The algorithm uses spatial filtering to estimate the signal-to-noise ratio (SNR) and attenuates time-frequency elements that have poor SNR. The algorithm was evaluated by measuring intelligibility of speech embedded in 4-talker babble where the interfering talkers were spatially separated and changed location during the test. Twelve cochlear implant users took part in the evaluation, which demonstrated a significant mean improvement of 4.6 dB (standard error 0.4, P < 0.001) in speech reception threshold compared to an adaptive beamformer. The results suggest that a substantial improvement in performance can be gained for cochlear implant users in noisy environments where the noise is spatially separated from the target speech. (C) 2013 Acoustical Society of America.
引用
收藏
页码:2412 / 2420
页数:9
相关论文
共 31 条
[21]   A NEW PORTABLE SOUND PROCESSOR FOR THE UNIVERSITY-OF-MELBOURNE NUCLEUS LIMITED MULTIELECTRODE COCHLEAR IMPLANT [J].
MCDERMOTT, HJ ;
MCKAY, CM ;
VANDALI, AE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (06) :3367-3371
[22]  
Meyer J, 1997, INT CONF ACOUST SPEE, P1167, DOI 10.1109/ICASSP.1997.596150
[23]  
Patrick James F, 2006, Trends Amplif, V10, P175, DOI 10.1177/1084713806296386
[24]   Speech understanding in background noise with the two-microphone adaptive beamformer BEAM™ in the nucleus Freedom™ cochlear implant system [J].
Spriet, Ann ;
Van Deun, Lieselot ;
Eftaxiadis, Kyriaky ;
Laneau, Johan ;
Moonen, Marc ;
van Dijk, Bas ;
van Wieringen, Astrid ;
Wouters, Jan .
EAR AND HEARING, 2007, 28 (01) :62-72
[25]   Speech perception as a function of electrical stimulation rate: Using the nucleus 24 cochlear implant system [J].
Vandali, AE ;
Whitford, LA ;
Plant, KL ;
Clarke, GM .
EAR AND HEARING, 2000, 21 (06) :608-624
[26]   EVALUATION OF A PORTABLE 2-MICROPHONE ADAPTIVE BEAMFORMING SPEECH PROCESSOR WITH COCHLEAR IMPLANT PATIENTS [J].
VANHOESEL, RJM ;
CLARK, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (04) :2498-2503
[27]   The Effect of Front-End Processing on Cochlear Implant Performance of Children [J].
Wolfe, Jace ;
Schafer, Erin C. ;
John, Andrew ;
Hudson, Mary .
OTOLOGY & NEUROTOLOGY, 2011, 32 (04) :533-538
[28]  
Wolff Tobias, 2008, 2008 Hands-Free Speech Communication and Microphone Arrays (HSCMA '08), P53, DOI 10.1109/HSCMA.2008.4538686
[29]   Speech recognition in noise for cochlear implantees with a two-microphone monaural adaptive noise reduction system [J].
Wouters, J ;
Vanden Berghe, J .
EAR AND HEARING, 2001, 22 (05) :420-430
[30]   A Dual-Microphone Algorithm That Can Cope With Competing-Talker Scenarios [J].
Yousefian, Nima ;