Sequencing of production-scale synthetic oligonucleotides by enriching for coupling failures using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:8
作者
Alazard, D
Filipowsky, M
Raeside, J
Clarke, M
Majlessi, M
Russell, J
Weisburg, W
机构
[1] GenProbe Inc, San Diego, CA 92121 USA
[2] Univ Strathclyde, Dept Chem, Glasgow G1 1XQ, Lanark, Scotland
关键词
oligonucleotide sequencing; MALDI-TOF mass spectrometry; crude synthetic oligonucleotide coupling failures; solid-phase extraction;
D O I
10.1006/abio.2001.5493
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A technique for sequencing oligonucleotides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry is described. The series of coupling failure species are extracted from the dimethoxytrityl-on, full-length oligonucleotide in crude synthetic material using C,, stationary-phase cartridges. These concentrated failure species can be easily detected by MALDI-TOF, which determines the mass difference between spectral ions to identify a particular base. The solid-phase extraction step greatly enhances ion signals and mass resolution, and sequencing information is generally obtained from the 5' end up to the first three to four nucleotides at the 3' end. Complete sequence can be generated in conjunction with snake venom phosphodiesterase digestion of purified material. This method eliminates difficulties associated with other mass spectrometric sequencing techniques involving oligonucleotide length; structure; and sugar, base, and backbone modifications. Examples of sequencing a 17-mer composed primarily of 2'-O-methylribonucleotides and a single nonnucleosidic linker and a mixed sugar backbone 51-mer with 2'-O-methylribonucleotides and a homopolymer tail are reported in this study. (C) 2001 Elsevier Science.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 61 条
[1]   ANTISENSE DNA OLIGONUCLEOTIDES .1. THE USE OF IONSPRAY TANDEM MASS-SPECTROMETRY FOR THE SEQUENCE VERIFICATION OF METHYLPHOSPHONATE OLIGODEOXYRIBONUCLEOTIDES [J].
BAKER, TR ;
KEOUGH, T ;
DOBSON, RLM ;
RILEY, TA ;
HASSELFIELD, JA ;
HESSELBERTH, PE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (03) :190-194
[2]   Base specificity of oligonucleotide digestion by calf spleen phosphodiesterase with matrix-assisted laser desorption ionization analysis [J].
Bentzley, CM ;
Johnston, MV ;
Larsen, BS .
ANALYTICAL BIOCHEMISTRY, 1998, 258 (01) :31-37
[3]   Oligonucleotide sequence and composition determined by matrix-assisted laser desorption ionization [J].
Bentzley, CM ;
Johnston, MV ;
Larsen, BS ;
Gutteridge, S .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2141-2146
[4]  
Boschenok J, 1996, RAPID COMMUN MASS SP, V10, P144, DOI 10.1002/(SICI)1097-0231(19960115)10:1<144::AID-RCM452>3.0.CO
[5]  
2-D
[6]  
Brown T., 1991, Oligonucleotides and analogues. A Practical Approach, P1
[7]   A sequencing method for RNA oligonucleotides based on mass spectrometry [J].
Faulstich, K ;
Worner, K ;
Brill, H ;
Engels, JW .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :4349-4353
[8]   THE ANALYSIS OF MOCK DNA-SEQUENCING REACTIONS USING MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY [J].
FITZGERALD, MC ;
ZHU, L ;
SMITH, LM .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) :895-897
[9]   Sequencing exons 5 to 8 of the p53 gene by MALDI-TOF mass spectrometry [J].
Fu, DJ ;
Tang, K ;
Braun, A ;
Reuter, D ;
Darnhofer-Demar, B ;
Little, DP ;
O'Donnell, MJ ;
Cantor, CR ;
Köster, H .
NATURE BIOTECHNOLOGY, 1998, 16 (04) :381-384
[10]   SEQUENCING OF OLIGONUCLEOTIDES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROSPRAY MASS-SPECTROMETRY [J].
GLOVER, RP ;
SWEETMAN, GMA ;
FARMER, PB ;
ROBERTS, GCK .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (10) :897-901