Influence of occlusal forces on stress distribution in preloaded dental implant screws

被引:138
作者
Alkan, I
Sertgöz, A
Ekici, E
机构
[1] Marmara Univ, Dishekimligi Fak, Sch Dent, Dept Prosthodont, TR-80200 Istanbul, Turkey
[2] Marmara Univ, Fac Engn, Dept Engn Mech, TR-80200 Istanbul, Turkey
关键词
D O I
10.1016/j.prosdent.2004.01.016
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Statement of problem. Abutment and prosthetic loosening of single and multiple screw-retained, implant-supported fixed partial dentures is a concern. Purpose. The purpose of this study was to investigate stress distribution of preloaded dental implant screws in 3 implant-to-abutment joint systems under simulated occlusal forces. Material and methods. Three abutment-to-implant joint systems were simulated by using the 3-dimensional finite element analysis method: (1) Branemark external hexagonal screw-retained abutment, (2) ITI 8-degree Morse tapered cemented abutment, and (3) ITI 8-degree Morse tapered plus internal octagonal screw-retained abutment. A thermal load and contact analysis method were used to simulate the preload resulting from the manufacturers' recommended torques in implant screw joint assemblies. The simulated preloaded implants were then loaded with 3 simulated static occlusal loads (10 N; horizontal, 35 N; vertical, 70 N; oblique) on the crown position onto the implant complex. Results. Numeric and graphical results demonstrated that the stresses increased in both the abutment and prosthetic screws in the finite clement models after simulated horizontal loading. However, when vertical and oblique static loads were applied, stresses decreased in the external hexagonal and internal octagonal plus 8-degree Morse tapered abutment and prosthetic screws with the exception of the prosthetic screw of ITI abutment after 70-N oblique loading. Stresses increased in the ITI 8-degree Morse tapered cemented abutment after both vertical and oblique loads. Conclusion. Although an increase or decrease was demonstrated for the maximum calculated stress values in preloaded screws after occlusal loads, these maximum stress values were well below the yield stress of both abutment and prosthetic screws of 2 implant systems tested. The results imply that the 3 implant-to-abutment joint systems tested may not fail under the simulated occlusal forces.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 26 条
[1]
REPLACEMENT OF MAXILLARY AND MANDIBULAR MOLARS WITH SINGLE ENDOSSEOUS IMPLANT RESTORATIONS - A RETROSPECTIVE STUDY [J].
BECKER, W ;
BECKER, BE .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (01) :51-55
[2]
Bickford JH, 1981, INTRO DESIGN BEHAV B, P528
[3]
Evaluation of the effectiveness of a technique to prevent screw loosening [J].
Binon, PP .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (04) :430-432
[4]
Carr A B, 1996, Int J Oral Maxillofac Implants, V11, P589
[5]
Examination of the implant-abutment interface after fatigue testing [J].
Cibirka, RM ;
Nelson, SK ;
Lang, BR ;
Rueggeberg, FA .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (03) :268-275
[6]
Application of finite element analysis in implant dentistry: A review of the literature [J].
Geng, JP ;
Tan, KBC ;
Liu, GR .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (06) :585-598
[7]
Micromotion and dynamic fatigue properties of the denial implant-abutment interface [J].
Gratton, DG ;
Aquilino, SA ;
Stanford, CM .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (01) :47-52
[8]
Haack J E, 1995, Int J Oral Maxillofac Implants, V10, P529
[9]
Dynamic fatigue properties of the dental implant-abutment interface: Joint opening in wide-diameter versus standard-diameter hex-type implants [J].
Hoyer, SA ;
Stanford, CM ;
Buranadham, S ;
Fridich, T ;
Wagner, J ;
Gratton, D .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (06) :599-607
[10]
JEMT T, 1991, International Journal of Oral and Maxillofacial Implants, V6, P29