Amplitude Doppler US: Slow blood flow detection tested with a flow phantom

被引:53
作者
Weskott, HP
机构
[1] Department of Internal Medicine II, Städtisches Krankenhaus Siloah, Hannover 30449
关键词
blood; flow dynamics; blood vessels; US; ultrasound; (US); Doppler studies; experimental; POWER; CAPILLARIES; SONOGRAPHY; VELOCITY;
D O I
10.1148/radiology.202.1.8988201
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the in vitro sensitivity for the detection of slow blood flow in tiny tubes with an amplitude Doppler ultrasound (US) technique at different angles and pulse repetition frequencies. MATERIALS AND METHODS: Human blood treated with heparin was pumped through silicone tubes (flow phantoms made by the author) with lumina of 3.00 mm, 0.30 mm, and 0.05 mm. Slow flow was imaged by using amplitude and color Doppler US techniques with two US devices at different pulse repetition frequencies and angles and in different sound propagation media. RESULTS: Under ideal conditions, the lowest detectable velocity was 0.04-0.06 cm/sec in the 3.00-mm tube. Detection was about three to four times less sensitive in the 0.30-mm and 0.05-mm tubes. Amplitude Doppler US sensitivity is only slightly dependent on the angle of incidence and propagation medium. CONCLUSION: The fractional volume flow determined the sensitivity of the amplitude Doppler technique for detecting low flow. Amplitude Doppler US is nearly angle independent; thus, it is superior to color Doppler US. Amplitude Doppler US is three to four times more sensitive when tubes have very tiny lumina and when probes of a lower frequency are used.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 11 条
[1]   RED BLOOD-CELL VELOCITY IN NAILFOLD CAPILLARIES OF MAN MEASURED BY A TELEVISION MICROSCOPY TECHNIQUE [J].
BOLLINGER, A ;
BUTTI, P ;
BARRAS, JP ;
TRACHSLER, H ;
SIEGENTHALER, W .
MICROVASCULAR RESEARCH, 1974, 7 (01) :61-72
[2]   POWER VERSUS CONVENTIONAL COLOR DOPPLER SONOGRAPHY - COMPARISON IN THE DEPICTION OF NORMAL INTRARENAL VASCULATURE [J].
BUDE, RO ;
RUBIN, JM ;
ADLER, RS .
RADIOLOGY, 1994, 192 (03) :777-780
[3]  
Evans DH., 1989, DOPPLER ULTRASOUND P
[4]   RELATIVE HEMATOCRIT IN HUMAN-SKIN CAPILLARIES AND ITS RELATION TO CAPILLARY BLOOD-FLOW VELOCITY [J].
FAGRELL, B ;
INTAGLIETTA, M ;
OSTERGREN, J .
MICROVASCULAR RESEARCH, 1980, 20 (03) :327-335
[5]  
HOSKINS PR, 1996, ULTRASOUND MED BIOL, V16, P141
[6]   DETECTION OF SOFT-TISSUE HYPEREMIA - VALUE OF POWER DOPPLER SONOGRAPHY [J].
NEWMAN, JS ;
ADLER, RS ;
BUDE, RO ;
RUBIN, JM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :385-389
[7]   PULSATILE FLOW MODEL WITH ELASTIC VESSELS FOR DUPLEX SONOGRAPHIC EXAMINATIONS [J].
PETRICK, J ;
SCHLIEF, R ;
ZOMACK, M ;
LANGHOLZ, J ;
URBANK, A .
ULTRASCHALL IN DER MEDIZIN, 1992, 13 (06) :277-282
[8]   FRACTIONAL MOVING BLOOD-VOLUME - ESTIMATION WITH POWER DOPPLER US [J].
RUBIN, JM ;
ADLER, RS ;
FOWLKES, JB ;
SPRATT, S ;
PALLISTER, JE ;
CHEN, JF ;
CARSON, PL .
RADIOLOGY, 1995, 197 (01) :183-190
[9]   POWER DOPPLER US - A POTENTIALLY USEFUL ALTERNATIVE TO MEAN FREQUENCY-BASED COLOR DOPPLER US [J].
RUBIN, JM ;
BUDE, RO ;
CARSON, PL ;
BREE, RL ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :853-856
[10]  
TWINING P, 1994, BMUS B, V2, P22