Advances in the voltammetric analysis of small biologically relevant compounds

被引:92
作者
Lawrence, NS
Beckett, EL
Davis, J
Compton, RG
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Univ Surrey, Dept Chem, Guildford GU2 7XH, Surrey, England
关键词
electroanalysis; voltammetry; electrochemical detection; review;
D O I
10.1006/abio.2002.5584
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The problems associated with attempting to apply voltammetric techniques to the analysis of biologically relevant organics within complex media are identified and, through reviewing the very recent literature (1999-mid-2001), possible solutions are described. The boundaries of the search were limited to research targeted at the resolution of specific problems, associated with quantitative determinations. Various strategies have emerged to counter problems of poor sensitivity and selectivity and these have been summarized and critically appraised. Where possible, the characteristics of each approach have been distilled into a table format to ease comparison. Emphasis has been placed on the collation of information that will improve the intrinsic electrode response and as such should be of value to those interested in pursing electroanalytical methodologies regardless of context. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:1 / 16
页数:16
相关论文
共 238 条
[1]  
Abou El-Nour K, 2000, ELECTROANAL, V12, P805
[2]   Anodic adsorptive voltammetric determination of the vitamin B1 (thiamine) [J].
Aboul-Kasim, E .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (06) :1047-1054
[3]  
Abu Zuhri AZ, 1999, ANAL LETT, V32, P2965, DOI 10.1080/00032719908543020
[4]   Analytical performance of cylindrical carbon fiber microelectrodes in low-permitivity organic solvents:: determination of vanillin in ethyl acetate [J].
Agüí, L ;
López-Guzmán, JE ;
González-Cortés, A ;
Yáñez-Sedeño, P ;
Pingarrón, JM .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :241-248
[5]  
Ahamad R, 2000, ELECTROANAL, V12, P1220, DOI 10.1002/1521-4109(200010)12:15<1220::AID-ELAN1220>3.3.CO
[6]  
2-U
[7]  
Akkermans RP, 1998, ELECTROANAL, V10, P814, DOI 10.1002/(SICI)1521-4109(199809)10:12<814::AID-ELAN814>3.0.CO
[8]  
2-W
[9]   Electrocatalytical properties of a potassium hexacyanoferrate (II) modified polypyrrole electrode.: Application to vitamin C determination [J].
Alonso, JG ;
Sánchez, CD ;
García, MLT ;
Barbado, MDV ;
Batanero, PS .
ANALYTICAL LETTERS, 1999, 32 (10) :1961-1980
[10]   Optimization of the experimental parameters in the determination of rifamycin SV by adsorptive stripping voltammetry [J].
Alonso, MA ;
Sanllorente, S ;
Sarabia, LA ;
Arcos, MJ .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :123-133