Advances in the voltammetric analysis of small biologically relevant compounds

被引:92
作者
Lawrence, NS
Beckett, EL
Davis, J
Compton, RG
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Univ Surrey, Dept Chem, Guildford GU2 7XH, Surrey, England
关键词
electroanalysis; voltammetry; electrochemical detection; review;
D O I
10.1006/abio.2002.5584
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The problems associated with attempting to apply voltammetric techniques to the analysis of biologically relevant organics within complex media are identified and, through reviewing the very recent literature (1999-mid-2001), possible solutions are described. The boundaries of the search were limited to research targeted at the resolution of specific problems, associated with quantitative determinations. Various strategies have emerged to counter problems of poor sensitivity and selectivity and these have been summarized and critically appraised. Where possible, the characteristics of each approach have been distilled into a table format to ease comparison. Emphasis has been placed on the collation of information that will improve the intrinsic electrode response and as such should be of value to those interested in pursing electroanalytical methodologies regardless of context. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:1 / 16
页数:16
相关论文
共 238 条
[81]  
Honeychurch KC, 2000, ELECTROANAL, V12, P171, DOI 10.1002/(SICI)1521-4109(200002)12:3<171::AID-ELAN171>3.0.CO
[82]  
2-Q
[83]   Voltammetric behavior of adriamycin and its determination at Ni ion-implanted electrode [J].
Hu, JB ;
Li, QL .
ANALYTICAL SCIENCES, 1999, 15 (12) :1215-1218
[84]   Powder microelectrodes for capillary electrophoresis with amperometric detection [J].
Hu, S ;
Zhang, M ;
Pang, DW ;
Cheng, JK .
ANALYTICAL SCIENCES, 2000, 16 (08) :807-810
[85]   Amperometric detection for capillary electrophoresis at a sol-gel carbon composite electrode [J].
Hua, L ;
Tan, SN .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :179-186
[86]  
Hua L, 2000, ELECTROANAL, V12, P287, DOI 10.1002/(SICI)1521-4109(20000301)12:4<287::AID-ELAN287>3.0.CO
[87]  
2-O
[88]   Voltammetric behaviour and determination of the anthracycline antitumor drug nogalamycin [J].
Ibrahim, MS .
ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) :105-112
[89]   Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection [J].
Inoue, K ;
Kato, K ;
Yoshimura, Y ;
Makino, T ;
Nakazawa, H .
JOURNAL OF CHROMATOGRAPHY B, 2000, 749 (01) :17-23
[90]   Amperometric detection of gaseous ethanol and acetaldehyde at low concentrations on an Au-Nafion electrode [J].
Jacquinot, P ;
Hodgson, AWE ;
Müller, B ;
Wehrli, B ;
Hauser, PC .
ANALYST, 1999, 124 (06) :871-876