Ptychographic X-ray Tomography of Silk Fiber Hydration

被引:47
作者
Esmaeili, Morteza [1 ]
Floystad, Jostein B. [1 ]
Diaz, Ana [2 ]
Hoydalsvik, Kristin [1 ]
Guizar-Sicairos, Manuel [2 ]
Andreasen, Jens W. [3 ]
Breiby, Dag W. [1 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Phys, N-7491 Trondheim, Norway
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Tech Univ Denmark, Imaging & Struct Anal Programme, Dept Energy Convers & Storage, DK-4000 Roskilde, Denmark
关键词
PRIMARY-WAVE FIELDS; PHASE DETERMINATION; DIFFRACTION; RESOLUTION; WATER;
D O I
10.1021/ma3021163
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Studying noninyasively the internal nanoporous structure of a single Tussah silk fiber under different humidity conditions, we demonstrate for the first time the feasibility of in-situ ptychographic tomography. The resulting 3D images of the silk fiber interior, obtained at both dry and humid conditions, yield quantitative information about the spatial density variations in the form of detailed maps of the size, shape, and orientation distributions of the nanopores inside the silk fiber, revealing that the fiber swells anisotropically in humid conditions, with the expansion taking place solely normal to the fiber axis. Exploiting quantitative information on the fiber's electron density, hydration was found to proceed through interaction with the silk protein rather than filling of pores.
引用
收藏
页码:434 / 439
页数:6
相关论文
共 31 条
[1]   Silk-based biomaterials [J].
Altman, GH ;
Diaz, F ;
Jakuba, C ;
Calabro, T ;
Horan, RL ;
Chen, JS ;
Lu, H ;
Richmond, J ;
Kaplan, DL .
BIOMATERIALS, 2003, 24 (03) :401-416
[2]  
[Anonymous], 1994, Kernel smoothing
[3]   Influence of the overlap parameter on the convergence of the ptychographical iterative engine [J].
Bunk, Oliver ;
Dierolf, Martin ;
Kynde, Soren ;
Johnson, Ian ;
Marti, Othmar ;
Pfeiffer, Franz .
ULTRAMICROSCOPY, 2008, 108 (05) :481-487
[4]   Quantitative x-ray phase nanotomography [J].
Diaz, Ana ;
Trtik, Pavel ;
Guizar-Sicairos, Manuel ;
Menzel, Andreas ;
Thibault, Pierre ;
Bunk, Oliver .
PHYSICAL REVIEW B, 2012, 85 (02)
[5]   Ptychographic X-ray computed tomography at the nanoscale [J].
Dierolf, Martin ;
Menzel, Andreas ;
Thibault, Pierre ;
Schneider, Philipp ;
Kewish, Cameron M. ;
Wepf, Roger ;
Bunk, Oliver ;
Pfeiffer, Franz .
NATURE, 2010, 467 (7314) :436-U82
[6]   Movable aperture lensless transmission microscopy: A novel phase retrieval algorithm [J].
Faulkner, HML ;
Rodenburg, JM .
PHYSICAL REVIEW LETTERS, 2004, 93 (02) :023903-1
[7]   Phase tomography from x-ray coherent diffractive imaging projections [J].
Guizar-Sicairos, Manuel ;
Diaz, Ana ;
Holler, Mirko ;
Lucas, Miriam S. ;
Menzel, Andreas ;
Wepf, Roger A. ;
Bunk, Oliver .
OPTICS EXPRESS, 2011, 19 (22) :21345-21357
[8]  
Hamedi M, 2007, NAT MATER, V6, P357, DOI [10.1038/nmat1884, 10.1038/nma11884]
[9]   An instrument for 3D x-ray nano-imaging [J].
Holler, M. ;
Raabe, J. ;
Diaz, A. ;
Guizar-Sicairos, M. ;
Quitmann, C. ;
Menzel, A. ;
Bunk, O. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07)