GRadient echo Acquisition for Superparamagnetic particles with positive contrast (GRASP): Sequence characterization in membrane and glass superparamagnetic iron oxide phantoms at 1.5T and 3T

被引:154
作者
Mani, V
Briley-Saebo, KC
Itskovich, VV
Samber, DD
Fayad, ZA
机构
[1] Mt Sinai Sch Med, Imaging Sci Labs, New York, NY 10029 USA
[2] Mt Sinai Sch Med, Dept Radiol, New York, NY USA
[3] Mt Sinai Sch Med, Zena & Michael A Wiener Cardiovasc Inst, Marie Josee & Henry R Kravis Cardiovasc Hlth Ctr, New York, NY USA
[4] Mt Sinai Sch Med, Dept Med, New York, NY USA
关键词
iron oxide; gradient echo imaging; susceptibility; T-2(*); positive contrast MRI;
D O I
10.1002/mrm.20739
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iron oxides are used for cell trafficking and identification of macrophages in plaque using MRI. Due to the negative contrast, differentiation between signal loss caused by iron and native low signal in tissue may be problematic. It is, therefore, preferable to achieve positive contrast. The purpose of this study was to test the efficacy of a new MRI sequence GRASP (GRe Acquisition for Superparamagnetic Particles) to generate a positive signal in phantoms containing iron. Membrane phantoms were constructed containing Ferumoxide at 7 concentrations. Standard GRE sequences were modified with user controlled z-gradient rephasing (+/- 100%). CNR values were determined as a function of echo time (TE) and % rephasing at 1.5T and 3T. T-2(star) values were determined using multiple double-echo GRE. The GRASP sequence generated positive signal enhancement in phantoms containing iron. For all rephasing values <= 30%, positive contrast was observed. The CNR generated at 1.5T was greater than the values at 3T for all concentrations tested. Correlation between CNR at 0% and 100% rephasing was observed at 1.5T(R = 0.84). Additionally, correlation between field change across the volume and CNR was observed. In conclusion, GRASP sequences may be used to generate positive signal enhancement in the presence of iron using MRI.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 25 条
[11]   PHYSICAL AND CHEMICAL-PROPERTIES OF SUPERPARAMAGNETIC IRON-OXIDE MR CONTRAST AGENTS - FERUMOXIDES, FERUMOXTRAN, FERUMOXSIL [J].
JUNG, CW ;
JACOBS, P .
MAGNETIC RESONANCE IMAGING, 1995, 13 (05) :661-674
[12]   Comparison of superparamagnetic iron oxide-enhanced and gadobenate dimeglumine-enhanced dynamic MRI for detection of small hepatocellular carcinomas [J].
Kim, YK ;
Kim, CS ;
Lee, YH ;
Kwak, HS ;
Lee, JM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) :1217-1223
[13]   Accumulation of ultrasmall superparamagnetic particles of iron oxide in human atherosclerotic plaques can be detected by in vivo magnetic resonance imaging [J].
Kooi, ME ;
Cappendijk, VC ;
Cleutjens, KBJM ;
Kessels, AGH ;
Kitslaar, PJEHM ;
Borgers, M ;
Frederik, PM ;
Daemen, MJAP ;
van Engelshoven, JMA .
CIRCULATION, 2003, 107 (19) :2453-2458
[14]   THE INFLUENCE OF PULSE SEQUENCE ON THE RELAXATION EFFECTS OF SUPERPARAMAGNETIC IRON-OXIDE CONTRAST AGENTS [J].
MAJUMDAR, S ;
ZOGHBI, SS ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (03) :289-301
[15]  
Ruehm SG, 2001, CIRCULATION, V103, P415
[16]   FERRITE PARTICLES - A SUPERPARAMAGNETIC MR CONTRAST AGENT FOR THE RETICULOENDOTHELIAL SYSTEM [J].
SAINI, S ;
STARK, DD ;
HAHN, PF ;
WITTENBERG, J ;
BRADY, TJ ;
FERRUCCI, JT .
RADIOLOGY, 1987, 162 (01) :211-216
[17]   Passive tracking exploiting local signal conservation: The white marker phenomenon [J].
Seppenwoolde, JH ;
Viergever, MA ;
Bakker, CJG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) :784-790
[18]  
STUBER M, 2005, P 13 ANN M ISMRM MIA
[19]   AMI-221-ENHANCED MR LYMPHOGRAPHY - USEFULNESS FOR DIFFERENTIATING REACTIVE FROM TUMOR-BEARING LYMPH-NODES [J].
VASSALLO, P ;
MATEI, C ;
HESTON, WDW ;
MCLACHLAN, SJ ;
KOUTCHER, JA ;
CASTELLINO, RA .
RADIOLOGY, 1994, 193 (02) :501-506
[20]   Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imaging [J].
Wang, YXJ ;
Hussain, SM ;
Krestin, GP .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2319-2331