Ultrasound three-dimensional velocity measurements by feature tracking

被引:24
作者
Bashford, GR
vonRamm, OT
机构
[1] Department of Biomédical Engineering, Duke University, Durham
关键词
D O I
10.1109/58.489394
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This article describes a new angle-independent method suitable for three-dimensional (3-D) blood how velocity measurement that tracks features of the ultrasonic speckle produced by a pulse echo system. In this method, a feature is identified and followed over time to detect motion. Other blood flow velocity measurement methods typically estimate velocity using one- (1-D) or two-dimensional (2-D) spatial and time information. Speckle decorrelation due to motion in the elevation dimension may hinder this estimate of the true 3-D blood flow velocity vector. Feature tracking is a 3-D method with the ability to measure the true blood velocity vector rather than a projection onto a line or plane. Off-line experiments using a tissue phantom and a real-time volumetric ultrasound imaging system have shown that the local maximum detected value of the speckle signal may be identified and tracked for measuring velocities typical of human blood flow. The limitations of feature tracking, including the uncertainty of the peak location and the duration of the local maxima are discussed. An analysis of the expected error using this method is given.
引用
收藏
页码:376 / 384
页数:9
相关论文
共 18 条
[1]   PULSED ULTRASONIC DOPPLER BLOOD-FLOW SENSING [J].
BAKER, DW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1970, SU17 (03) :170-&
[2]   SPECKLE STRUCTURE IN 3 DIMENSIONS [J].
BASHFORD, GR ;
VONRAMM, OT .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (01) :35-42
[3]   A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION [J].
BOHS, LN ;
TRAHEY, GE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) :280-286
[4]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[5]   2-DIMENSIONAL RANDOM ARRAYS FOR REAL-TIME VOLUMETRIC IMAGING [J].
DAVIDSEN, RE ;
JENSEN, JA ;
SMITH, SW .
ULTRASONIC IMAGING, 1994, 16 (03) :143-163
[6]   EFFECT OF THE BEAM-VESSEL ANGLE ON THE RECEIVED ACOUSTIC-SIGNAL FROM BLOOD [J].
FERRARA, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (03) :416-428
[7]   MULTIPLE CROSSED-BEAM ULTRASOUND DOPPLER VELOCIMETRY [J].
FOX, MD .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (05) :281-286
[8]  
GIBSON JW, 1989, PRINCIPLES ANALOG DI, P115
[9]   EFFECTS OF SPECKLE ON RESOLUTION [J].
KOZMA, A ;
CHRISTENSEN, CR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (11) :1257-1260
[10]   ULTRASONICALLY TISSUE-MIMICKING LIVER INCLUDING THE FREQUENCY-DEPENDENCE OF BACKSCATTER [J].
MADSEN, EL ;
ZAGZEBSKI, JA ;
INSANA, MF ;
BURKE, TM ;
FRANK, G .
MEDICAL PHYSICS, 1982, 9 (05) :703-710