Three-dimensional optical coherence tomography of the embryonic murine cardiovascular system

被引:60
作者
Luo, Wei
Marks, Daniel L.
Ralston, Tyler S.
Boppart, Stephen A.
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Bioengn, Urbana, IL 61801 USA
[3] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Med, Urbana, IL 61801 USA
关键词
imaging; optical coherence tomography; cardiovascular malfunction; embryology; functional genomics;
D O I
10.1117/1.2193465
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is an emerging highresolution real-time biomedical imaging technology that has potential as a novel investigational tool in developmental biology and functional genomics. In this study, murine embryos and embryonic hearts are visualized with an OCT system capable of 2-mu m axial and 15-mu m lateral resolution and with real-time acquisition rates. We present, to our knowledge, the first sets of high-resolution 2- and 3-D OCT images that reveal the internal structures of the mammalian (murine) embryo (E10.5) and embryonic (E14.5 and E17.5) cardiovascular system. Strong correlations are observed between OCT images and corresponding hematoxylin- and eosin-stained histological sections. Real-time in vivo embryonic (E10.5) heart activity is captured by spectral-domain optical coherence tomography, processed, and displayed at a continuous rate of five frames per second. With the ability to obtain not only high-resolution anatomical data but also functional information during cardiovascular development, the OCT technology has the potential to visualize and quantify changes in murine development and in congenital and induced heart disease, as well as enable a wide range of basic in vitro and in vivo research studies in functional genomics. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:8
相关论文
共 31 条
[1]  
[Anonymous], 2000, The Laboratory Mouse
[2]   Optical probes and techniques for molecular contrast enhancement in coherence imaging [J].
Boppart, SA ;
Oldenburg, AL ;
Xu, CY ;
Marks, DL .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[3]   Forward-imaging instruments for optical coherence tomography [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Tearney, GJ ;
Fujimoto, JG ;
Brezinski, ME .
OPTICS LETTERS, 1997, 22 (21) :1618-1620
[4]   Intraoperative assessment of microsurgery with three-dimensional optical coherence tomography [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Southern, JF ;
Brezinski, ME ;
Fujimoto, JG .
RADIOLOGY, 1998, 208 (01) :81-86
[5]   Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography [J].
Boppart, SA ;
Tearney, GJ ;
Bouma, BE ;
Southern, JF ;
Brezinski, ME ;
Fujimoto, JG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (09) :4256-4261
[6]   Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Bilinsky, IP ;
Golubovic, B ;
Fujimoto, JG .
OPTICS LETTERS, 1996, 21 (22) :1839-1841
[7]   Tissue Doppler gated (TDOG) dynamic three-dimensional ultrasound imaging of the fetal heart [J].
Brekke, S ;
Tegnander, E ;
Torp, HG ;
Eik-Nes, SH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 24 (02) :192-198
[8]   A three-dimensional model of the mouse at embryonic day 9 [J].
Brune, RM ;
Bard, JBL ;
Dubreuil, C ;
Guest, E ;
Hill, W ;
Kaufman, M ;
Stark, M ;
Davidson, D ;
Baldock, RA .
DEVELOPMENTAL BIOLOGY, 1999, 216 (02) :457-468
[9]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[10]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069