We present theoretical and experimental results which demonstrate the superior sensitivity of swept source ( SS) and Fourier domain (FD) optical coherence tomography (OCT) techniques over the conventional time domain (TD) approach. We show that SS- and FD-OCT have equivalent expressions for system signal-to-noise ratio which result in a typical sensitivity advantage of 20-30dB over TD-OCT. Experimental verification is provided using two novel spectral discrimination (SD) OCT systems: a differential fiber-based 800nm FD-OCT system which employs deep-well photodiode arrays, and a differential 1300 nm SS- OCT system based on a swept laser with an 87 nm tuning range. (C) 2003 Optical Society of America.
引用
收藏
页码:2183 / 2189
页数:7
相关论文
共 16 条
  • [1] Optical coherence tomography using a frequency-tunable optical source
    Chinn, SR
    Swanson, EA
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1997, 22 (05) : 340 - 342
  • [2] CHOMA MA, 2003, IN PRESS OPT LETT
  • [3] Spectral resolution and sampling issues in Fourier-transform spectral interferometry
    Dorrer, C
    Belabas, N
    Likforman, JP
    Joffre, M
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (10) : 1795 - 1802
  • [4] MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY
    FERCHER, AF
    HITZENBERGER, CK
    KAMP, G
    ELZAIAT, SY
    [J]. OPTICS COMMUNICATIONS, 1995, 117 (1-2) : 43 - 48
  • [5] Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser
    Golubovic, B
    Bouma, BE
    Tearney, GJ
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1997, 22 (22) : 1704 - 1706
  • [6] CHIRP OPTICAL COHERENCE TOMOGRAPHY OF LAYERED SCATTERING MEDIA
    Haberland, U. H. P.
    Blazek, V.
    Schmitt, H. J.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (03) : 259 - 266
  • [7] Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
  • [8] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [9] Performance of fourier domain vs. time domain optical coherence tomography
    Leitgeb, R
    Hitzenberger, CK
    Fercher, AF
    [J]. OPTICS EXPRESS, 2003, 11 (08): : 889 - 894
  • [10] Wavelength-tuning interferometry of intraocular distances
    Lexer, F
    Hitzenberger, CK
    Fercher, AF
    Kulhavy, M
    [J]. APPLIED OPTICS, 1997, 36 (25): : 6548 - 6553