Stereotactic biopsy of ductal carcinoma in situ of the breast using an 11-gauge vacuum-assisted device: Persistent underestimation of disease

被引:69
作者
Won, B [1 ]
Reynolds, HE [1 ]
Lazaridis, CL [1 ]
Jackson, VP [1 ]
机构
[1] Indiana Univ Hosp, Dept Radiol, Sch Med, Indianapolis, IN 46202 USA
关键词
D O I
10.2214/ajr.173.1.10397131
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the diagnostic accuracy of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy techniques in the diagnosis of ductal carcinoma in situ of the breast. MATERIALS AND METHODS. We retrospectively reviewed 41 consecutive lesions that had been diagnosed as ductal carcinoma in situ using stereotactic needle biopsy. The first 21 lesions had been biopsied using a 14-gauge automated gun; the remaining 20 lesions, using an 11-gauge vacuum-assisted device. Surgical histopathologic results at lumpectomy were compared with the findings at needle biopsy and defined as either concordant, when only ductal carcinoma in situ (i.e., no evidence of invasive carcinoma) was evident at surgery, or discordant, when invasive carcinoma was found. One patient from the automated gun group was lost to follow-up and was not included in the analysis. RESULTS. Invasive carcinoma was found at surgery in seven (35%) of the 20 cases diagnosed using the automated gun compared with three (15%) of the 20 cases diagnosed using the vacuum-assisted device (p =.13). In all three of these discordant vacuum-assisted cases, only microinvasive disease was found at surgery. However, in only two of the seven discordant automated gun cases was only microinvasive disease found at surgery. CONCLUSION. The 11-gauge directional vacuum-assisted biopsy technique may improve the accuracy of ductal carcinoma in situ diagnosis. Underestimation of disease still occurs, however.
引用
收藏
页码:227 / 229
页数:3
相关论文
共 9 条
[1]   Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model [J].
Berg, WA ;
Krebs, TL ;
Campassi, C ;
Magder, LS ;
Sun, CCJ .
RADIOLOGY, 1997, 205 (01) :203-208
[2]   Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy [J].
Brenner, RJ ;
Fajardo, L ;
Fisher, PR ;
Dershaw, DD ;
Evans, WP ;
Bassett, L ;
Feig, S ;
Mendelson, E ;
Jackson, V ;
Margolin, FR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) :341-346
[3]   Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy [J].
Burbank, F .
RADIOLOGY, 1997, 202 (03) :843-847
[4]   STEREOTAXIC LARGE-CORE NEEDLE-BIOPSY OF 450 NONPALPABLE BREAST-LESIONS WITH SURGICAL CORRELATION IN LESIONS WITH CANCER OR ATYPICAL HYPERPLASIA [J].
JACKMAN, RJ ;
NOWELS, KW ;
SHEPARD, MJ ;
FINKELSTEIN, SI ;
MARZONI, FA .
RADIOLOGY, 1994, 193 (01) :91-95
[5]   Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy [J].
Liberman, L ;
Dershaw, DD ;
Rosen, PP ;
Morris, EA ;
Abramson, AF ;
Borgen, PV .
RADIOLOGY, 1998, 206 (03) :711-715
[6]   STEREOTAXIC CORE BIOPSY OF BREAST-CARCINOMA - ACCURACY AT PREDICTING INVASION [J].
LIBERMAN, L ;
DERSHAW, DD ;
ROSEN, PP ;
GIESS, CS ;
COHEN, MA ;
ABRAMSON, AF ;
HANN, LE .
RADIOLOGY, 1995, 194 (02) :379-381
[7]   From the RSNA refresher courses - Performing a breast biopsy with a directional, vacuum-assisted biopsy instrument [J].
Parker, SH ;
Klaus, AJ .
RADIOGRAPHICS, 1997, 17 (05) :1233-1252
[8]   PERCUTANEOUS LARGE-CORE BREAST BIOPSY - A MULTIINSTITUTIONAL STUDY [J].
PARKER, SH ;
BURBANK, F ;
JACKMAN, RJ ;
AUCREMAN, CJ ;
CARDENOSA, G ;
CINK, TM ;
COSCIA, JL ;
EKLUND, GW ;
EVANS, WP ;
GARVER, PR ;
GRAMM, HF ;
HAAS, DK ;
JACOB, KM ;
KELLY, KM ;
KILLEBREW, LK ;
LECHNER, MC ;
PERLMAN, SJ ;
SMID, AP ;
TABAR, L ;
TABER, FE ;
WYNN, RT .
RADIOLOGY, 1994, 193 (02) :359-364
[9]   STEREOTAXIC BREAST BIOPSY WITH A BIOPSY GUN [J].
PARKER, SH ;
LOVIN, JD ;
JOBE, WE ;
LUETHKE, JM ;
HOPPER, KD ;
YAKES, WF ;
BURKE, BJ .
RADIOLOGY, 1990, 176 (03) :741-747