Biocompatible carbon-based screen-printed electrodes for the electrochemical detection of nitric oxide

被引:49
作者
Miserere, S
Ledru, S
Ruillé, N
Griveau, S
Boujtita, M
Bedioui, F
机构
[1] Ecole Natl Super Chim Paris, Unite Pharmacol Chim & Genet, CNRS, UMR 8151,U640, F-75231 Paris 05, France
[2] Fac Sci & Tech, Grp Methodol Electrochim, LAIEM, CNRS,UMR 6006,FCMN,FR 2465, F-44322 Nantes 03, France
关键词
screen-printed carbon electrodes; biocompatibility; electrochemical sensors; nitric oxide; sessile drop contact angle measurements;
D O I
10.1016/j.elecom.2005.11.016
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report in this study oil the first use of carbon-based screen-printed electrodes (SPCEs) for the development of inexpensive, disposable and biocompatible electrochemical sensors for NO in solution. First, the screen printing electrode process was performed oil two types of substrates and the chemical modification of the obtained electrodes was achieved in order to endow them with the desired sensitivity, selectivity and biocompatibility. The first important step in building the sensor system consisted into transposing existing chemical modifications to design selective and sensitive coatings towards NO. The second major and novel step of this work was devoted to confer to the electrode material the desired biocompatibility character by overcoating the whole chemically modified SPCEs with an additional layer of poly-oxyethyleneglycol (PEG) polymers. Since the biocompatible property of materials is generally linked to their hydrophilic character, the biocompatibility of the designed electrodes was assessed by sessile drop contact angle measurements. Finally, the performances of the electrodes towards NO were evaluated by chronoamperometric measurements. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 24 条
[1]   Practical aspects and methodological approaches to achieve electrochemical detection of submicromolar NO in biological systems [J].
Bedioui, F ;
Trevin, S .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :227-230
[2]   Elaboration and use of nickel planar macrocyclic complex-based sensors for the direct electrochemical measurement of nitric oxide in biological media [J].
Bedioui, F ;
Trevin, S ;
Devynck, J ;
Lantoine, F ;
Brunet, A ;
Devynck, MA .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (03) :205-212
[3]   Electrochemical nitric oxide sensors for biological samples - Principle, selected examples and applications [J].
Bedioui, F ;
Villeneuve, N .
ELECTROANALYSIS, 2003, 15 (01) :5-18
[4]   o-phenylenediamine-modified carbon fiber electrodes for the detection of nitric oxide [J].
Friedemann, MN ;
Robinson, SW ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2621-2628
[5]   Some recent designs and developments of screen-printed carbon electrochemical sensors/biosensors for biomedical, environmental, and industrial analyses [J].
Hart, JP ;
Crew, A ;
Crouch, E ;
Honeychurch, KC ;
Pemberton, RM .
ANALYTICAL LETTERS, 2004, 37 (05) :789-830
[6]  
LEDRU S, IN PRESS BIOSENS BIO
[7]   Improved planar amperometric nitric oxide sensor based on platinized platinum anode. 2. Direct real-time measurement of NO generated from porcine kidney slices in the presence of L-arginine, L-arginine polymers, and protamine [J].
Lee, Y ;
Yang, J ;
Rudich, SM ;
Schreiner, RJ ;
Meyerhoff, ME .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :545-551
[8]   NITRIC-OXIDE RELEASE FROM A SINGLE CELL MEASURED INSITU BY A PORPHYRINIC-BASED MICROSENSOR [J].
MALINSKI, T ;
TAHA, Z .
NATURE, 1992, 358 (6388) :676-678
[9]  
MALMSTEN M, 2005, LANGMUIR, V21, P4809
[10]  
MAURITZ KA, 1988, J MACROMOL SCI REV M, V68, P64