Biocompatible carbon-based screen-printed electrodes for the electrochemical detection of nitric oxide

被引:49
作者
Miserere, S
Ledru, S
Ruillé, N
Griveau, S
Boujtita, M
Bedioui, F
机构
[1] Ecole Natl Super Chim Paris, Unite Pharmacol Chim & Genet, CNRS, UMR 8151,U640, F-75231 Paris 05, France
[2] Fac Sci & Tech, Grp Methodol Electrochim, LAIEM, CNRS,UMR 6006,FCMN,FR 2465, F-44322 Nantes 03, France
关键词
screen-printed carbon electrodes; biocompatibility; electrochemical sensors; nitric oxide; sessile drop contact angle measurements;
D O I
10.1016/j.elecom.2005.11.016
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report in this study oil the first use of carbon-based screen-printed electrodes (SPCEs) for the development of inexpensive, disposable and biocompatible electrochemical sensors for NO in solution. First, the screen printing electrode process was performed oil two types of substrates and the chemical modification of the obtained electrodes was achieved in order to endow them with the desired sensitivity, selectivity and biocompatibility. The first important step in building the sensor system consisted into transposing existing chemical modifications to design selective and sensitive coatings towards NO. The second major and novel step of this work was devoted to confer to the electrode material the desired biocompatibility character by overcoating the whole chemically modified SPCEs with an additional layer of poly-oxyethyleneglycol (PEG) polymers. Since the biocompatible property of materials is generally linked to their hydrophilic character, the biocompatibility of the designed electrodes was assessed by sessile drop contact angle measurements. Finally, the performances of the electrodes towards NO were evaluated by chronoamperometric measurements. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 24 条
[21]   Electropolymerized nickel macrocyclic complex-based films: Design and electrocatalytic application [J].
Trevin, S ;
Bedioui, F ;
Villegas, MGG ;
BiedCharreton, C .
JOURNAL OF MATERIALS CHEMISTRY, 1997, 7 (06) :923-928
[22]   Electrochemical and spectrophotometric study of the behavior of electropolymerized nickel porphyrin films in the determination of nitric oxide in solution [J].
Trevin, S ;
Bedioui, F ;
Devynck, J .
TALANTA, 1996, 43 (03) :303-311
[23]   Reduced mouse fibroblast cell growth by increased hydrophilicity of microbial polyhydroxyalkanoates via hyaluronan coating [J].
Wang, YW ;
Wu, Q ;
Chen, GQ .
BIOMATERIALS, 2003, 24 (25) :4621-4629
[24]   Integrated compact biocompatible hydrogel-based amperometric sensing device for easy screening of drugs involved in nitric oxide production by adherent cultured cells [J].
Wartelle, C ;
Schuhmann, W ;
Blöchl, A ;
Bedioui, F .
ELECTROCHIMICA ACTA, 2005, 50 (25-26) :4988-4994