The relationship of acoustic emission and pulse-repetition frequency in the detection of gas body stability and cell death

被引:13
作者
Samuel, S [1 ]
Miller, DL [1 ]
Fowlkes, JB [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
ultrasound; bioeffects; cell damage; contrast agent; acoustic emission;
D O I
10.1016/j.ultrasmedbio.2005.11.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The effect of pulse-repetition frequency (PRF) and number of exposures on membrane damage and subsequent death of contrast agent-attached phagocytic cells was examined. Phagocytic cells of a mouse macrophage cell line were grown as monolayers on thin Mylar sheets. Optison(R) microbubbles were attached to these cells by incubation. Focused ultrasound exposures (P-r = 2 MPa) were implemented at a frequency of 2.25 MHz with 46 cycle pulses and clinically relevant PRFs of I kHz, 100 Hz, 10 Hz, 1 Hz and 0.1 Hz in a degassed water bath. A 1-MHz receive transducer measured the scattered signal. The frequency spectrum was normalized to a control spectrum from linear scatterers. Photomicrographs of the cell monolayer were made before and after exposure, and a dye exclusion test (Trypan blue) was used to find the percentage of blue-stained cells indicating cell death, which was then related to acoustic emission. For 10 acoustic pulses and a high prerinse gas body concentration, there was less cell death and correspondingly lower change in the acoustic emissions at a PRF of I kHz than with PRFs of 100 Hz, 10 Hz, I Hz and 0.1 Hz (p < 0.001). The reduced effect at high PRF may be indicative of some evolution of the shelled microbubble that requires significant total exposure duration (> 10 ms, but < 100 ms).
引用
收藏
页码:439 / 447
页数:9
相关论文
共 28 条
[1]  
*AIUM, 2000, J ULTRAS MED, V19, P167
[2]  
Amararene A, 2001, ULTRASON, P1751, DOI 10.1109/ULTSYM.2001.992059
[3]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[4]  
COOPER M, 2004, P 2004 IEEE INT ULTR, V3, P1808
[5]   A preliminary evaluation of the effects of primary and secondary radiation forces on acoustic contrast agents [J].
Dayton, PA ;
Morgan, KE ;
Klibanov, ALS ;
Brandenburger, G ;
Nightingale, KR ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1264-1277
[6]   Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro [J].
Everbach, EC ;
Makin, IRS ;
Azadniv, M ;
Meltzer, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (04) :619-624
[7]   TRANSIENT PULSATIONS OF SMALL GAS-BUBBLES IN WATER [J].
FLYNN, HG ;
CHURCH, CC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (03) :985-998
[8]  
Forsberg F, 2001, ULTRASOUND CONTRAST, P15
[9]  
Fowlkes JB, 1998, PROG OBST GYN SONOG, P73
[10]   Delineation of experimental liver tumors in rabbits by a new ultrasound contrast agent and stimulated acoustic emission [J].
Hauff, P ;
Fritzsch, T ;
Reinhardt, M ;
Weitschies, W ;
Luders, F ;
Uhlendorf, V ;
Heldmann, D .
INVESTIGATIVE RADIOLOGY, 1997, 32 (02) :94-99