Development of a new high-efficiency thermal ionization source for mass spectrometry

被引:20
作者
Duan, YX [1 ]
Chamberlin, EP [1 ]
Olivares, JA [1 ]
机构
[1] LOS ALAMOS NATL LAB,CHEM SCI & TECHNOL DIV,LOS ALAMOS,NM 87545
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1997年 / 161卷 / 1-3期
关键词
thermal ionization; ion source; high efficiency; quadrupole; mass spectrometry; isotope separation; isotope ratios; instrumentation;
D O I
10.1016/S0168-1176(96)04434-5
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A thermal ionization source for mass spectrometry has been designed and tested. The ion source is based on a tungsten crucible with a deep cavity into which the sample is loaded. The crucible is heated by high energy electron bombardment from a tantalum filament surrounding the crucible. As the sample evaporates inside the crucible, gaseous analyte atoms are produced which interact with the inner surface of the crucible walls to produce positive ions through surface ionization. The ions are extracted from the cavity through a small opening at the end of the crucible. Regulation of the electron emission current makes it possible to control the energy and power applied to the crucible and, therefore, the crucible temperature. A number of elements have been tested in this source. The ionization efficiencies measured using a high transmission isotope separator spectrometer show 10 to 100 times higher efficiency than in conventional surface thermal ionization sources. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:27 / 39
页数:13
相关论文
共 36 条
[1]   DETERMINATION OF URANIUM AND THORIUM CONCENTRATIONS IN SOILS - COMPARISON OF ISOTOPE-DILUTION SECONDARY ION MASS-SPECTROMETRY AND ISOTOPE-DILUTION THERMAL IONIZATION MASS-SPECTROMETRY [J].
ADRIAENS, AG ;
FASSETT, JD ;
KELLY, WR ;
SIMONS, DS ;
ADAMS, FC .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :2945-2950
[2]   THERMO-IONIZATION EFFICIENCY IN ION-SOURCE CAVITY [J].
AFANASEV, VP ;
OBUKHOV, VA ;
RAIKO, VI .
NUCLEAR INSTRUMENTS & METHODS, 1977, 145 (03) :533-536
[3]   SIMULTANEOUS DETERMINATION OF THE U-235/U-238 ISOTOPE RATIO AND CONCENTRATION AT NANOGRAM LEVELS OF URANIUM EMPLOYING A MIXED SPIKE IN THERMAL IONIZATION MASS-SPECTROMETRY [J].
AGGARWAL, SK ;
DUGGAL, RK ;
SHAH, PM ;
JAIN, HC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1988, 85 (02) :137-150
[4]   EXPERIMENTS WITH SURFACE IONIZATION INTEGRATED TARGET-ION SOURCE OF SOLIS [J].
AMIEL, S ;
ENGLER, G ;
NIREL, Y ;
SHMID, M .
NUCLEAR INSTRUMENTS & METHODS, 1976, 139 (DEC15) :305-309
[5]   NEW METHOD FOR RARE-EARTH ISOTOPE SEPARATION [J].
BEYER, GJ ;
HERRMANN, E ;
PIOTROWSKI, A ;
RAIKO, VJ ;
TYRROFF, H .
NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (03) :437-+
[6]  
BEYER GJ, 1972, RADIOCHEM RADIOANAL, V12, P259
[7]  
*CERN, 1970, 703 CERN
[8]   MEASUREMENT OF THE BEAM ENERGY SPREAD FROM A MICROWAVE ION-SOURCE [J].
CHAMBERLIN, EP ;
LEUNG, KN ;
WALTHERS, S ;
BIBEAU, RA ;
STICE, RL ;
KELLEY, GM ;
WILSON, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 26 (1-3) :227-234
[9]   A METHODOLOGY FOR THE ISOTOPIC CHARACTERIZATION OF NATURAL URANIUM TO BE USED AS REFERENCE MATERIAL FOR THERMAL IONIZATION MASS-SPECTROMETRY [J].
CRETELLA, RF ;
LUKASZEW, RA ;
MARRERO, JG ;
SERVANT, R .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 98 (02) :99-106