Association between plasma levels of D-dimer and fibrinogen/fibrin degradation products (FDP) for exclusion of thromboembolic disorders

被引:49
作者
Moresco, RN [1 ]
Halla, R
Vargas, LCR
Silla, LMD
机构
[1] Univ Fed Rio Grande Sul, Dept Hematol & Bone Marrow Transplantat, Hosp Clin Porto Alegre, Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande Sul, Dept Postgrad Med Sci, Fac Med, Porto Alegre, RS, Brazil
[3] Santa Casa Univ Hosp, Clin Chem Lab, Porto Alegre, RS, Brazil
关键词
D-dimer; fibrinogen; fibrin degradation products (FDP); thromboembolism; immunoassays;
D O I
10.1007/s11239-006-4837-9
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: D-dimer and fibrinogen/fibrin degradation products (FDP) levels are elevated in subjects with thromboembolic disorders, and the assays for detection of D-dimer and FDP are used in many laboratories for the investigation of these disorders. The aim of this study was to evaluate the association between the plasma levels of D-dimer and FDP in the investigation of thromboembolic disorders. Methods: D-dimer and FDP immunoassays were performed in 217 consecutive blood samples from subjects with suspected of thromboembolic disorders by use of Liatest D-dimer and Plasma FDP. Results: FDP results were classified in: < 5, 5-20, > 20 mu g/mL, and D-dimer levels obtained in these groups ranged to 350-1210 ng/mL, 420-1960 ng/mL, and 1190-51170 ng/mL, respectively. A significant association between D-dimer levels and the reaction times necessary to occur agglutination in latex agglutination test for FDP was observed. Conclusions: There was an association between plasma levels of D-dimer and FDP. The preliminary determination of FDP levels could be useful because it allows estimating the D-dimer levels before of the automated systems analysis, reducing costs associated to dilutions of plasma samples.
引用
收藏
页码:199 / 202
页数:4
相关论文
共 21 条
[1]
A new scoring system for the detailed description of the distribution and thrombotic burden in deep leg vein thrombosis [J].
Björgell, O ;
Nilsson, PE ;
Svensson, PJ ;
Bergqvist, D .
ANGIOLOGY, 1999, 50 (03) :179-187
[2]
MEASUREMENT OF D-DIMER IN PLASMA AS DIAGNOSTIC-AID IN SUSPECTED PULMONARY-EMBOLISM [J].
BOUNAMEAUX, H ;
CIRAFICI, P ;
DEMOERLOOSE, P ;
SCHNEIDER, PA ;
SLOSMAN, D ;
REBER, G ;
UNGER, PF .
LANCET, 1991, 337 (8735) :196-200
[3]
ELEVATED CONCENTRATIONS OF CROSS-LINKED FIBRIN DEGRADATION PRODUCTS IN PLASMA - AN EARLY MARKER OF GRAM-NEGATIVE BACTEREMIA [J].
DEITCHER, SR ;
EISENBERG, PR .
CHEST, 1993, 103 (04) :1107-1112
[4]
A new quantitative D-dimer assay appropriate in emergency: Reliability of the assay for pulmonary embolism exclusion diagnosis [J].
Duet, M ;
Benelhadj, S ;
Kedra, W ;
Vilain, D ;
Ajzenberg, C ;
Elkharrat, D ;
Drouet, L ;
Soria, C ;
Mundler, O .
THROMBOSIS RESEARCH, 1998, 91 (01) :1-5
[5]
D-dimer levels and risk of recurrent venous thromboembolism [J].
Eichinger, S ;
Minar, E ;
Bialonczyk, C ;
Hirschl, M ;
Quehenberger, P ;
Schneider, B ;
Weltermann, A ;
Wagner, O ;
Kyrle, PA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (08) :1071-1074
[6]
Escoffre-Barbe M, 1998, AM J CLIN PATHOL, V109, P748
[7]
FLORES J, 1995, RESPIRATION, V62, P258
[8]
ASSESSMENT OF FIBRIN DEGRADATION PRODUCTS DURING FIBRINOLYTIC THERAPY FOR ACUTE MYOCARDIAL-INFARCTION [J].
FRANCIS, CW ;
CONNAGHAN, DG ;
MARDER, VJ .
CIRCULATION, 1986, 74 (05) :1027-1036
[9]
GABAZZA EC, 1992, CANCER-AM CANCER SOC, V70, P2631, DOI 10.1002/1097-0142(19921201)70:11<2631::AID-CNCR2820701111>3.0.CO
[10]
2-9