Kinetics of antigen binding to antibody microspots:: Strong limitation by mass transport to the surface

被引:94
作者
Kusnezow, W
Syagailo, YV
Rüffer, S
Klenin, K
Sebald, W
Hoheisel, JD
Gauer, C
Goychuk, I
机构
[1] Deutsch Krebsforschungszentrum, Div Funct Genome Anal, D-69120 Heidelberg, Germany
[2] Deutsch Krebsforschungszentrum, Div Biophys & Macromol, D-6900 Heidelberg, Germany
[3] Univ Wurzburg, Dept Physiol Chem 2, Bioctr, Wurzburg, Germany
[4] Advalytix AG, Brunnthal, Germany
[5] Univ Augsburg, Inst Phys, D-8900 Augsburg, Germany
关键词
antibody microarray; mass-transport limited reaction; microspot kinetics; two-compartment model;
D O I
10.1002/pmic.200500149
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is well documented that diffusion has generally a strong effect on the binding kinetics in the microtiter plate immunoassays. However, a systematic quantitative experimental evaluation of the microspot kinetics is still missing in the literature. Our work aims at filling this important gap of knowledge on the example of antigen binding to antibody microspots. A mathematical model was derived within the framework of two-compartment model and applied to the quantitative analysis of the experimental data obtained for typical antibody microspot assays. A strong mass-transport dependence of the antigen-antibody microspot kinetics was identified to be one of the main restrictions of this new technology. The binding reactions are slowed down in the microspot immunoassays by several orders of magnitude as compared with the corresponding well-stirred bulk reactions. The task to relax the mass-transport limitations should thus be one of the most important issues in designing the antibody microarrays. These limitations notwithstanding, the detection range of more than five orders of magnitude and the high sensitivity in the low femtomolar range were experimentally achieved in our study, demonstrating thus an enormous potential of this highly capable technology.
引用
收藏
页码:794 / 803
页数:10
相关论文
共 35 条
[1]  
Adam G., 1968, Reduction of dimensionality in biological diffusion processes in Structural Chemistry and Molecular Biology, Ved
[2]   Gains in sensitivity with a device that mixes microarray hybridization solution in a 25-μm-thick chamber [J].
Adey, NB ;
Lei, M ;
Howard, MT ;
Jensen, JD ;
Mayo, DA ;
Butel, DL ;
Coffin, SC ;
Moyer, TC ;
Slade, DE ;
Spute, MK ;
Hancock, AM ;
Eisenhoffer, GT ;
Dalley, BK ;
McNeely, MR .
ANALYTICAL CHEMISTRY, 2002, 74 (24) :6413-6417
[3]   Toward optimized antibody microarrays:: a comparison of current microarray support materials [J].
Angenendt, P ;
Glökler, J ;
Murphy, D ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :253-260
[4]   Solid supports in enzyme-linked immunosorbent assay and other solid-phase immunoassays [J].
Butler, JE .
METHODS-A COMPANION TO METHODS IN ENZYMOLOGY, 2000, 22 (01) :4-23
[5]   The biophysics of DNA hybridization with immobilized oligonucleotide probes [J].
Chan, V ;
Graves, DJ ;
McKenzie, SE .
BIOPHYSICAL JOURNAL, 1995, 69 (06) :2243-2255
[6]   On the Lambert W function [J].
Corless, RM ;
Gonnet, GH ;
Hare, DEG ;
Jeffrey, DJ ;
Knuth, DE .
ADVANCES IN COMPUTATIONAL MATHEMATICS, 1996, 5 (04) :329-359
[7]   DEVELOPING MULTIANALYTE ASSAYS [J].
EKINS, RP ;
CHU, F .
TRENDS IN BIOTECHNOLOGY, 1994, 12 (03) :89-94
[8]  
Ekins RP, 1998, CLIN CHEM, V44, P2015
[9]  
Goldstein B, 1999, J MOL RECOGNIT, V12, P293, DOI 10.1002/(SICI)1099-1352(199909/10)12:5<293::AID-JMR472>3.3.CO
[10]  
2-D