Influence of measuring conditions on the quantification of spectroscopic signals in TA-FTIR-MS systems

被引:15
作者
Eigenmann, F [1 ]
Maciejewski, M [1 ]
Baiker, A [1 ]
机构
[1] ETH Honggerberg, Swiss Fed Inst Technol, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
关键词
calibration techniques; hyphenated techniques; pulse TA combined with FTIR; quantitative evolved gas analysis; TA-FTIR-MS;
D O I
10.1007/s10973-005-7387-z
中图分类号
O414.1 [热力学];
学科分类号
摘要
Simultaneous thermal analysis (TA) and evolved gas analysis by mass spectrometry (MS) and/or Fourier transform infrared spectroscopy (FTIR) is a powerful hyphenated technique combining direct measurement of mass loss and sensitive spectroscopic analysis. In the present study the influence of several experimental parameters which may affect the quantification of FTIR signals have been studied using a combined TA-FTIR-MS system. Parameters studied include: sample mass (1-400 mg), carrier gas flow rate (25-200 mL min(-1)), resolution of the FTIR spectrometer (1-32 cm(-1)), and location of injection of the calibrating gas. MS analysis, which was not significantly affected by the experimental conditions, was used as a reference for assessing the accuracy of quantification by FTIR. The quantification of the spectroscopic signals was verified by the decomposition (NaHCO3) or dehydration (CuSO4 center dot 5H(2)O) of compounds with well-known stoichiometry. The systematic study of the parametric sensitivity revealed that spectral resolution and carrier gas flow rate, which affect the acquisition time in the IR-cell, are key parameters that must be adjusted carefully for reliable quantification. The dependence of the reliability of quantification on these parameters is illustrated and conditions leading to proper quantification are discussed. As an example, for a standard spectral resolution of 4 cm(-1) and a FTIR gas cell volume of 8.7 mL, the carrier gas flow must be lower than 100 mL min(-1) for warranting accurate results (relative deviation < 2%). The concentration range of analyzed species is limited but can be extended by proper selection of the wavenumber regions for molecules giving strong IR signals.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 24 条
[11]   Approach to quantitative analysis of dynamic mixture IR spectra using TG/FT-IR [J].
Liau, LCK ;
Yang, TCK ;
Viswanath, DS .
APPLIED SPECTROSCOPY, 1997, 51 (06) :905-909
[12]   Novel pulse thermal analysis method and its potential for investigating gas-solid reactions [J].
Maciejewski, M ;
Muller, CA ;
Tschan, R ;
Emmerich, WD ;
Baiker, A .
THERMOCHIMICA ACTA, 1997, 295 (1-2) :167-182
[13]   Quantitative calibration of mass spectrometric signals measured in coupled TA-MS system [J].
Maciejewski, M ;
Baiker, A .
THERMOCHIMICA ACTA, 1997, 295 (1-2) :95-105
[14]   Advanced pulse calibration techniques for the quantitative analysis of TG-FTIR data [J].
Marsanich, K ;
Barontini, F ;
Cozzani, V ;
Petarca, L .
THERMOCHIMICA ACTA, 2002, 390 (1-2) :153-168
[15]   Thermogravimetry infrared spectroscopy (TG-FTIR) coupled analysis [J].
Materazzi, S .
APPLIED SPECTROSCOPY REVIEWS, 1997, 32 (04) :385-404
[16]   TG-FTIR COUPLED ANALYSIS APPLIED TO THE STUDIES IN UROLITHIASIS - CHARACTERIZATION OF HUMAN RENAL CALCULI [J].
MATERAZZI, S ;
CURINI, R ;
DASCENZO, G ;
MAGRI, AD .
THERMOCHIMICA ACTA, 1995, 264 :75-93
[17]   Mass spectrometry coupled to thermogravimetry (TG-MS) for evolved gas characterization: A review. [J].
Materazzi, S .
APPLIED SPECTROSCOPY REVIEWS, 1998, 33 (03) :189-218
[18]   QUANTITATIVE TG IR [J].
MITTLEMAN, M .
THERMOCHIMICA ACTA, 1990, 166 :301-308
[19]   Vapour phase Fourier transform infrared spectrometric determination of carbonate in sediments [J].
Pérez-Ponce, A ;
Garrigues, JM ;
Garrigues, S ;
de la Guardia, M .
ANALYST, 1998, 123 (09) :1817-1821
[20]   Evolved gas analysis of some solid fuels by TG-FTIR [J].
Pitkänen, I ;
Huttunen, J ;
Halttunen, H ;
Vesterinen, R .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 1999, 56 (03) :1253-1259