Supported capillary membrane sampling-gas chromatography on a valve with a pulsed discharge photoionization detector

被引:10
作者
Emmert, GL [1 ]
Brown, MA
Liao, ZH
Cao, G
Duty, C
机构
[1] Univ Memphis, Dept Chem, Memphis, TN 38152 USA
[2] Arkansas State Univ, Dept Chem, State Univ, AR 72467 USA
[3] Arkansas State Univ, Program Environm Sci, State Univ, AR 72467 USA
关键词
pulsed discharge photoionization detector; gas chromatography; water analysis; trihalomethanes (THM4); disinfection by-products;
D O I
10.1016/j.aca.2005.12.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The objective of this study was to develop and evaluate a simple miniaturized approach to gas chromatography termed supported capillary membrane sampling-gas chromatography on a valve (SCMS-GCOV). The prototype instrument uses a pulsed discharge photoionization detector (PDPID) as the GC detector. Two different analyzers were constructed. The first used a bench scale SCMS-GC. The second was a miniaturized SCMS-GCOV analyzer. The SCMS-GCOV analyzer was used to monitor the concentrations of trihalomethanes (THM4) in drinking water. Details are given for the construction of the SCMS-GC-PDPID and the SCMS-GCOV-PDPID analyzers. The results of method detection limit, accuracy and precision studies are reported for analysis of THM4 and are compared to other methods of THM4 analysis. Side-by-side comparison studies are conducted between the SCMS-GCOV and USEPA 502.2 with promising results. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 206
页数:10
相关论文
共 26 条
[1]  
[Anonymous], 5242 USEPA
[2]   CONTINUOUS-FLOW METHOD FOR DETERMINATION OF TOTAL TRIHALOMETHANES IN DRINKING-WATER WITH MEMBRANE-SEPARATION [J].
AOKI, T ;
KAWAKAMI, K .
WATER RESEARCH, 1989, 23 (06) :739-742
[3]   USE OF A PERMEATION SAMPLER FOR DETERMINATION OF VOLATILE PRIORITY POLLUTANTS [J].
BLANCHARD, RD ;
HARDY, JK .
ANALYTICAL CHEMISTRY, 1984, 56 (09) :1621-1624
[4]   On-line monitoring trihalomethanes in chlorinated water by membrane introduction-fast gas chromatography mass-spectrometry [J].
Chang, CC ;
Her, GR .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (01) :169-175
[5]   On-line monitoring of trihalomethanes in drinking water using continuous-flow purge and cryofocusing gas chromatography-mass spectrometry [J].
Chen, TC ;
Her, GR .
JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) :229-235
[6]  
Emmert Gary L., 2004, METHODS REAL TIME ME
[7]   Measuring trihalomethane concentrations in water using supported capillary membrane sampling-gas chromatography [J].
Emmert, GL ;
Cao, G ;
Duty, C ;
Wolcott, W .
TALANTA, 2004, 63 (03) :675-682
[8]  
*EPA, 1996, 814B96002 EPA, P37
[9]   Measuring the concentrations of drinking water disinfection by-products using capillary membrane sampling-flow injection analysis [J].
Geme, G ;
Brown, MA ;
Simone, P ;
Emmert, GL .
WATER RESEARCH, 2005, 39 (16) :3827-3836
[10]   TRACE ANALYSES FOR WASTEWATERS [J].
GLASER, JA ;
FOERST, DL ;
MCKEE, GD ;
QUAVE, SA ;
BUDDE, WL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (12) :1426-1435