Label-free cancer markers detection by capacitance biochip

被引:45
作者
Carrara, Sandro [1 ]
Bhalla, Viiayender [1 ]
Stagni, Claudio [1 ,2 ]
Benini, Luca [2 ]
Ferretti, Anna [1 ]
Valle, Francesco [1 ]
Gallotta, Andrea [3 ]
Ricco, Bruno [2 ]
Samori, Bruno [1 ]
机构
[1] Univ Bologna, Dept Biochem, I-40126 Bologna, Italy
[2] Univ Bologna, DEIS Dept, I-40126 Bologna, Italy
[3] Xeptagen SpA, Venice, Italy
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2009年 / 136卷 / 01期
关键词
Cancer markers detection; Capacitance biosensors; Ethylene-glycol materials; Alkanethiols; Cold electrodes; SELF-ASSEMBLED MONOLAYERS; QUARTZ-CRYSTAL MICROBALANCE; GOLD; IMMOBILIZATION; BIOSENSOR; ANTIGEN; BINDING; IMMUNOSENSORS; AFM;
D O I
10.1016/j.snb.2008.09.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper investigates technological advancements in developing reliable technologies for label free detection of cancer markers. Capacitance detection was used successfully to develop an immunosensor. Rigorous probe immobilization was implemented to obtain reliable capacitance measurements. The commonly considered alkanethiols for proteins immobilization do not allow sufficiently stable capacitance measurements. Therefore, new ethylene-glycol functionalized alkanethiols were used as more suitable materials to develop lab-on-a-chip detection of cancer markers. Results from AFM, Chemi-luminescence, Fluorescence, Cyclic Voltammetry. QCM, and capacitance measurements showed that three (ethyleneglycol) alkanethiols highly stabilized the sensing surfaces in time. The measured capacitance on the antibody layers was in the range of 60-70 nF/cm(2) and 80-115 nF/cm(2) for the antigen detection. The developed system was utilized to detect the Hepatocarcinoma marker SCCA, and the whole IgM fraction from Hepatocarcinoma patient's serum. Electrode by electrode reproducibility within the same chip increased by one order of magnitude (variations were reduced from 30-40% down to less than 2%) using these new alkanethiols, while the reached limit in sensitivity was close to 2.43 mu g/ml. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 53 条
[1]  
BALASUBRAMANIAN A, 2005, IEEE SENS J, P1
[2]   An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step [J].
Berggren, C ;
Bjarnason, B ;
Johansson, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (10) :1061-1068
[3]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[4]  
2-B
[5]   Capacitance measurements of antibody-antigen interactions in a flow system [J].
Berggren, C ;
Johansson, G .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3651-3657
[6]  
Berggren C, 1999, ELECTROANAL, V11, P156, DOI 10.1002/(SICI)1521-4109(199903)11:3<156::AID-ELAN156>3.0.CO
[7]  
2-O
[8]   Macroporous silicon based capacitive affinity sensor-fabrication and electrochemical studies [J].
Betty, CA ;
Lal, R ;
Sharma, DK ;
Yakhmi, JV ;
Mittal, JP .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 97 (2-3) :334-343
[9]  
BHALLA V, THIN SOLID FIL UNPUB
[10]   Comparison of random and oriented immobilisation of antibody fragments on mixed self-assembled monolayers [J].
Bonroy, Kristien ;
Frederix, Filip ;
Reekmans, Gunter ;
Dewolf, Ellen ;
De Palma, Randy ;
Borghs, Gustaaf ;
Declerck, Paul ;
Goddeeris, Bruno .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 312 (1-2) :167-181