Dynamic metal speciation analysis in aquatic ecosystems is emerging as a powerful basis for development of predictions of bioavailability and reliable risk assessment strategies. A given speciation sensor is characterized by an effective time scale or kinetic window that defines the measurable metal species via their labilities. Here we review the current state of the art for the theory and application of dynamic speciation sensors. We show that a common dynamic interpretation framework, based on rigorous flux expressions incorporating the relevant diffusion and reaction steps, is applicable for a suite of sensors that span a range of time scales. Interpolation from a kinetic spectrum of speciation data is proposed as a practical strategy for addressing questions of bicavailability. Case studies illustrate the practical significance of knowledge on the dynamic features of metal complex species in relation to biouptake, and highlight the limitations of equilibrium-based models.
引用
收藏
页码:8545 / 8556
页数:12
相关论文
共 117 条
[1]  
Alfaro-De la Torre MC, 2000, ANAL CHIM ACTA, V418, P53, DOI 10.1016/S0003-2670(00)00946-6
[2]  
[Anonymous], Z ELECTROCHEM
[3]  
[Anonymous], SITU MONITORING AQUA
[4]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   Gel-integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media [J].
Belmont-Hébert, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
de Rooij, NF ;
Koudelka-Hep, M .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2949-2956
[7]   THE INFERENCE OF INTRACELLULAR ENZYMATIC PROPERTIES FROM KINETIC DATA OBTAINED ON LIVING CELLS .1. SOME KINETIC CONSIDERATIONS REGARDING AN ENZYME ENCLOSED BY A DIFFUSION BARRIER [J].
BEST, JB .
JOURNAL OF CELLULAR AND COMPARATIVE PHYSIOLOGY, 1955, 46 (01) :1-27
[8]   Mass transfer limitation of biotransformation: Quantifying bioavailability [J].
Bosma, TNP ;
Middeldorp, PJM ;
Schraa, G ;
Zehnder, AJB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (01) :248-252
[9]   Evaluation of the free ion activity model of metal-organism interaction: extension of the conceptual model [J].
Brown, PL ;
Markich, SJ .
AQUATIC TOXICOLOGY, 2000, 51 (02) :177-194
[10]   Voltammetric environmental trace-metal analysis and speciation:: from laboratory to in situ measurements [J].
Buffle, J ;
Tercier-Waeber, ML .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :172-191