Comparison of skin blood flow between mini- and standard-incision approaches during total hip arthroplasty

被引:23
作者
Kiyama, Takahiko [1 ]
Naito, Masatoshi [1 ]
Shitama, Hiroshi [1 ]
Tsuyoshi, Shinoda [1 ]
Maeyama, Akira [1 ]
机构
[1] Fukuoka Univ, Sch Med, Dept Orthopaed Surg, Jonan Ku, Fukuoka 8140180, Japan
关键词
total hip arthroplasty; mini incision; surgical approach; skin blood flow;
D O I
10.1016/j.arth.2007.09.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Twenty patients who underwent total hip arthroplasty were randomly allocated to have surgery through a mini incision of <= 8 cm (mini-incision surgery [MIS] group, n = 10) or a standard incision of 14 cm (standard group, n = 10). A laser Doppler flowmeter was used to measure the intraoperative blood flow of the skin. The measurements were performed at 2 regions, specifically, anterior and posterior regions across the middle points of skin incision. The measurements were taken before making the incision and after implantation. As a control, the skin blood flow over the anterior superior iliac spine was measured. After implantation, mean skin blood flows at both regions in the MIS group were significantly decreased by 32% and 33%. However, the corresponding flows in standard group and control regions were constant during operation.
引用
收藏
页码:1045 / 1049
页数:5
相关论文
共 12 条
[1]
Minimally invasive total hip arthroplasty - A prospective randomized study [J].
Chimento, GF ;
Pavone, V ;
Sharrock, N ;
Kahn, B ;
Cahill, J ;
Sculco, TP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (02) :139-144
[2]
Mini-incision technique for total hip arthroplasty with navigation [J].
DiGioia, AM ;
Plakseychuk, AY ;
Levison, TJ ;
Jaramaz, B .
JOURNAL OF ARTHROPLASTY, 2003, 18 (02) :123-128
[3]
THE VALIDITY AND PRACTICALITY OF SUN-REACTIVE SKIN TYPE-I THROUGH TYPE-VI [J].
FITZPATRICK, TB .
ARCHIVES OF DERMATOLOGY, 1988, 124 (06) :869-871
[4]
Minimal-incision total hip arthroplasty [J].
Goldstein, WM ;
Branson, JJ ;
Berland, KA ;
Gordon, AC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :33-38
[5]
Hida S, 2003, SUPINE, V1, P85
[6]
Minimally invasive versus standard incision anterolateral hip replacement: a comparative study [J].
Howell, JR ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2004, 35 (02) :153-+
[7]
Total hip arthroplasty through a minimally invasive anterior surgical approach [J].
Kennon, RE ;
Keggi, JM ;
Wetmore, RS ;
Zatorski, LE ;
Huo, MH ;
Keggi, KJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :39-48
[8]
Comparison of scars from total hip replacements done with a standard or a mini-incision [J].
Mow, CS ;
Woolson, ST ;
Ngarmukos, SG ;
Park, EH ;
Lorenz, HP .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :80-85
[9]
EVALUATION OF LASER-DOPPLER FLOWMETRY AS A MEASURE OF TISSUE BLOOD-FLOW [J].
SMITS, GJ ;
ROMAN, RJ ;
LOMBARD, JH .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) :666-672
[10]
Waldman BJ, 2003, ORTHOPEDICS, V26, pS833