Thickness measurements on cell monolayers using CR-39 detectors

被引:11
作者
Dörschel, B [1 ]
Hermsdorf, D
Pieck, S
Starke, S
Thiele, H
机构
[1] Dresden Univ Technol, Dept Phys, Inst Radiat Protect Phys, D-01062 Dresden, Germany
[2] Dresden Univ Technol, Inst Zool, Dept Biol, D-01062 Dresden, Germany
关键词
cell thickness; solid state nuclear track detector; alpha particles; track diameter; track length; thickness fluctuations;
D O I
10.1016/S0168-583X(01)01148-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Interpretation of radiation effects on living cells requires the determination of the absorbed dose. Dosimetry in cell monolayers irradiated by charged particles needs the knowledge of the mean cell thickness. Thickness measurement was made utilising the energy alteration of alpha particles traversing the cell monolayers. The reduced energy was determined from diameters or lengths of etched tracks produced by the penetrating alpha particles in CR-39. The experiments were performed using 3T3 cells grown directly on the CR-39 surface. The reliability of the method has been studied by means of a detailed error analysis. The total thickness errors are composed of the measurement uncertainty and the fluctuations of the cell thickness within the monolayers. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:525 / 534
页数:10
相关论文
共 8 条
[1]   Measurement of the track etch rates along proton and alpha particle trajectories in CR-39 and calculation of the detection efficiency [J].
Dörschel, B ;
Bretschneider, R ;
Hermsdorf, D ;
Kadner, K ;
Kühne, H .
RADIATION MEASUREMENTS, 1999, 31 (1-6) :103-108
[2]  
Dorschel B, 1998, RADIAT PROT DOSIM, V78, P205, DOI 10.1093/oxfordjournals.rpd.a032353
[3]   The program StopPow -: A useful tool for computation of energy loss and range of light ions in SSNTDs [J].
Dörschel, B ;
Henniger, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 171 (04) :423-430
[4]  
Dorschel B, 1997, RADIAT PROT DOSIM, V69, P267, DOI 10.1093/oxfordjournals.rpd.a031913
[5]   THICKNESS MEASUREMENTS ON LIVING CELL MONOLAYERS BY NUCLEAR METHODS [J].
DURANTE, M ;
GIALANELLA, G ;
GROSSI, GF ;
PUGLIESE, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 73 (04) :543-549
[6]   Nuclear track detectors in cellular radiation biology [J].
Durante, M ;
Grossi, GF ;
Pugliese, M ;
Gialanella, G .
RADIATION MEASUREMENTS, 1996, 26 (02) :179-186
[7]   Monte Carlo simulation of single cell irradiation by an electron microbeam [J].
Miller, JH ;
Resat, MS ;
Metting, NF ;
Wei, K ;
Lynch, DJ ;
Wilson, WE .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2000, 39 (03) :173-177
[8]  