Comparison between a personal PM10 sampling head and the tapered element oscillating microbalance (TEOM) system

被引:31
作者
Soutar, A
Watt, M
Cherrie, JW
Seaton, A [1 ]
机构
[1] Univ Aberdeen, Sch Med, Dept Environm & Occupat Med, Aberdeen AB25 2ZD, Scotland
[2] Inst Occupat Med, Edinburgh EH8 9SV, Midlothian, Scotland
关键词
environment; particulate matter; personal exposure; epidemiology;
D O I
10.1016/S1352-2310(99)00227-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new personal PM10 sampling head has been developed by the Institute of Occupational Medicine (IOM), Edinburgh. The purpose of this study was to compare its performance in the field with the accepted fixed-location PM10 sampler, the tapered element oscillating microbalance (TEOM). The comparisons were carried out on three separate occasions during 1997 at each of two city centre locations in the UK. On each occasion two personal IOM PM10 sampling heads were located adjacent to a TEOM monitor and four successive sets of 24-h filter samples were collected. The data was compared with 24-h average TEOM concentrations, calculated as the arithmetic mean of the recorded hourly averages. There was a statistically significant linear relationship between the two types of monitor, although the concentrations from the IOM PM10 samplers were consistently higher than the TEOM data. It is therefore possible to use the regression equations presented in this paper to correct ambient PM10 concentrations measured by either method to equivalent values. Further research is needed to properly understand the reason for the difference between the TEOM and filter samplers. (C) 1999 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4373 / 4377
页数:5
相关论文
共 10 条
[1]   Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas [J].
Allen, G ;
Sioutas, C ;
Koutrakis, P ;
Reiss, R ;
Lurmann, FW ;
Roberts, PT .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) :682-689
[2]  
ARMITAGE P, 1994, STAT METHODS MED RES, P292
[3]  
*HSE, 1997, 142 HSE BOOKS
[4]  
*ISO, CD7708 INT STAND ORG
[5]   A NEW PERSONAL SAMPLER FOR AIRBORNE TOTAL DUST IN WORKPLACES [J].
MARK, D ;
VINCENT, JH .
ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (01) :89-&
[6]  
MEYER MB, 1995, PART MATT HLTH REG I
[7]   REVIEW OF EPIDEMIOLOGICAL EVIDENCE OF HEALTH-EFFECTS OF PARTICULATE AIR-POLLUTION [J].
POPE, CA ;
DOCKERY, DW ;
SCHWARTZ, J .
INHALATION TOXICOLOGY, 1995, 7 (01) :1-18
[8]  
RICKARD A, 1996, CLEAN AIR, V26, P37
[9]  
SMITH S, 1997, CLEAN AIR, V27, P70
[10]   INDIVIDUAL EXPOSURE TO PARTICULATE AIR-POLLUTION AND ITS RELEVANCE TO THRESHOLDS FOR HEALTH-EFFECTS - A STUDY OF TRAFFIC WARDENS [J].
WATT, M ;
GODDEN, D ;
CHERRIE, J ;
SEATON, A .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1995, 52 (12) :790-792