Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas

被引:232
作者
Allen, G [1 ]
Sioutas, C [1 ]
Koutrakis, P [1 ]
Reiss, R [1 ]
Lurmann, FW [1 ]
Roberts, PT [1 ]
机构
[1] SONOMA TECHNOL INC, SANTA ROSA, CA USA
关键词
D O I
10.1080/10473289.1997.10463923
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Increased interest in the health effects of ambient particulate mass (PM) has focused attention on the evaluation of existing mass measurement methodologies and the definition of PM in ambient air. The Rupprecht and Patashnick Tapered Element Oscillating MicroBalance (TEOM(R)) method for PM is compared with time-integrated gravimetric (manual) PM methods in large urban areas during different seasons. Comparisons are conducted for both PM10 and PM2.5 concentrations. In urban areas, a substantial fraction of ambient PM can be semi-volatile material. A larger fraction of this component of PM10 may be lost from the TEOM-heated filter than the Federal Reference Method (FRM). The observed relationship between TEOM and FRM methods varied widely among sites and seasons. In East Coast urban areas during the summer, the methods were highly correlated with good agreement. In the winter, correlation was somewhat lower, with TEOM PM concentrations generally lower than the FRM. Rubidoux, CA, and two Mexican sites (Tlalnepantla and Merced) had the highest levels of PM10 and the largest difference between TEOM and manual methods. PM2.5 data from collocation of 24-hour manual samples with the TEOM are also presented. As most of the semi-volatile PM is in the fine fraction, differences between these methods are larger for PM2.5 than for PM10.
引用
收藏
页码:682 / 689
页数:8
相关论文
共 13 条
[1]   A NEIGHBORHOOD-SCALE STUDY OF PM-10 SOURCE CONTRIBUTIONS IN RUBIDOUX, CALIFORNIA [J].
CHOW, JC ;
LIU, CS ;
CASSMASSI, J ;
WATSON, JG ;
LU, ZQ ;
PRITCHETT, LC .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (04) :693-706
[2]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[3]   ACUTE RESPIRATORY EFFECTS OF PARTICULATE AIR-POLLUTION [J].
DOCKERY, DW ;
POPE, CA .
ANNUAL REVIEW OF PUBLIC HEALTH, 1994, 15 :107-132
[4]  
FINLAYSONPITTS BJ, 1986, ATM CHEM FUND EXP TE
[5]   DESIGN OF A GLASS IMPACTOR FOR AN ANNULAR DENUDER FILTER PACK SYSTEM [J].
KOUTRAKIS, P ;
WOLFSON, JM ;
BRAUER, M ;
SPENGLER, JD .
AEROSOL SCIENCE AND TECHNOLOGY, 1990, 12 (03) :607-612
[6]   AN INTERCOMPARISON OF THE INDOOR AIR SAMPLING IMPACTOR AND THE DICHOTOMOUS SAMPLER FOR A 10-MU-M CUT SIZE [J].
LIOY, PJ ;
WAINMAN, T ;
TURNER, W ;
MARPLE, VA .
JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (05) :668-670
[7]   LOW FLOW-RATE SHARP CUT IMPACTORS FOR INDOOR AIR SAMPLING - DESIGN AND CALIBRATION [J].
MARPLE, VA ;
RUBOW, KL ;
TURNER, W ;
SPENGLER, JD .
JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1987, 37 (11) :1303-1307
[8]  
MEYER MB, 1995, PART MATT HLTH REG I
[9]   CONTINUOUS PM-10 MEASUREMENTS USING THE TAPERED ELEMENT OSCILLATING MICROBALANCE [J].
PATASHNICK, H ;
RUPPRECHT, EG .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (08) :1079-1083
[10]  
POPE CA, 1995, AM J RESP CRIT CARE, V151, P669, DOI 10.1164/ajrccm/151.3_Pt_1.669