Development of a high-performance liquid chromatography retention index scale for toxicological drug screening

被引:19
作者
Elliott, SP
Hale, KA
机构
[1] Regl. Laboratory for Toxicology, City Hosp. N.H.S. Teaching Trust, Birmingham B18 7QH, Dudley Road
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 694卷 / 01期
关键词
toxicol drugs;
D O I
10.1016/S0378-4347(97)00095-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient and practical analytical method for correcting HPLC retention data has been produced using an HPLC diode-array UV detector system. The system is based on retention indices (RI) and is to be used primarily for the identification of toxicologically relevant drugs involved in clinical and forensic toxicology. The RI correction method was chosen as it provided a slightly greater degree of reproducibility than using relative retention time (RRT), particularly for acidic and neutral drugs. Development of the system involved the establishment of the optimal chromatographic conditions and extensive studies of the stability of the system. An acetonitrile gradient elution was used with RI values determined by interpolation from a series of specifically chosen basic and acidic/neutral marker drugs which eluted at regular intervals to produce a linear RI scale. It was found that two separate RI scales were required for basic and acidic/neutral drugs. The use of multiple drug markers as primary retention index standards had not been previously applied to HPLC general drug screening and comparison with a recently published database suggests that the system may also provide improved selectivity.
引用
收藏
页码:99 / 114
页数:16
相关论文
共 23 条
[1]  
BAKER JK, 1979, J CHROMATOGR, V167, P107
[2]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DATABASE OF RETENTION INDEXES AND UV SPECTRA OF TOXICOLOGICALLY RELEVANT SUBSTANCES AND ITS INTERLABORATORY USE [J].
BOGUSZ, M ;
ERKENS, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 674 (1-2) :97-126
[3]   INFLUENCE OF ELUTION CONDITIONS ON HPLC RETENTION INDEX VALUES OF SELECTED ACIDIC AND BASIC DRUGS MEASURED IN THE 1-NITROALKANE SCALE [J].
BOGUSZ, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :174-178
[4]   STANDARDIZED HPLC/DAD SYSTEM, BASED ON RETENTION INDEXES AND SPECTRAL LIBRARY, APPLICABLE FOR SYSTEMATIC TOXICOLOGICAL SCREENING [J].
BOGUSZ, M ;
WU, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :188-197
[5]   INFLUENCE OF BIOLOGICAL MATRIX ON CHROMATOGRAPHIC BEHAVIOR AND DETECTION OF SELECTED ACIDIC, NEUTRAL, AND BASIC DRUGS EXAMINED BY MEANS OF A STANDARDIZED HPLC DAD SYSTEM [J].
BOGUSZ, M ;
ERKENS, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (01) :49-55
[6]   USE OF CORRECTED RETENTION INDEXES BASED ON 1-NITROALKANE AND ALKYL ARYLKETONE SCALES FOR HPLC IDENTIFICATION OF BASIC DRUGS [J].
BOGUSZ, M ;
NEIDLFISCHER, G ;
ADERJAN, R .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (06) :325-329
[7]   CORRECTED RETENTION INDEXES IN HPLC - THEIR USE FOR THE IDENTIFICATION OF ACIDIC AND NEUTRAL-DRUGS [J].
BOGUSZ, M ;
ADERJAN, R .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (02) :67-72
[8]   CALCULATION OF SOLUTE RETENTION FOR PH GRADIENT ELUTION HPLC EXPERIMENTS USING SINGLE AND COUPLED COLUMNS [J].
BUCK, CF ;
TOMELLINI, SA .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (04) :166-171
[9]   SCREENING FOR ACIDIC AND NEUTRAL-DRUGS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY IN POST-MORTEM BLOOD [J].
CHAN, EM ;
CHAN, SC .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1984, 8 (04) :173-176
[10]  
DFG TIAFT, 1992, SPEC ISS TIAFT B