Effects of repetitive freeze-thawing cycles on T2 and T2*of the Achilles tendon

被引:27
作者
Chang, Eric Y. [1 ,2 ]
Bae, Won C. [2 ]
Statum, Sheronda [2 ]
Du, Jiang [2 ]
Chung, Christine B. [1 ,2 ]
机构
[1] VA San Diego Healthcare Syst, Dept Radiol, San Diego, CA 92161 USA
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
Achilles tendon; Freeze-thaw; T2; T2*; UTE; BIOMECHANICAL PROPERTIES; MRI; CARTILAGE; VIVO; T1;
D O I
10.1016/j.ejrad.2013.10.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Introduction: In this study we sought to evaluate the effects of multiple freezing and thawing cycles on two MR parameters to study Achilles tendon, T2 and T2*. Materials and methods: Four fresh Achilles tendons were imaged on a 3T clinical scanner and again after 1, 2, 4, and 5 freeze-thaw cycles with spin-echo (SE) and ultrashort echo time (UTE) sequences. Regions of interest were manually drawn over the entire Achilles tendon and mono-exponential curves were used to determine T2 and T2* relaxation times. Results: There was no statistically significant difference in mean T2 or T2* values between the fresh specimens and after subsequent cycles of freeze-thaw treatment (p > 0.1). Linear regression between SE T2 values at baseline and after successive freeze-thaw cycles demonstrated moderate agreement (r = 0.60) whereas UTE T2* values at baseline and after successive-freeze thaw cycles demonstrated strong agreement (r = 0.92). Conclusion: These findings suggest that changes between specimens seen in vitro are due to factors other than frozen storage. Furthermore, our results suggest that there is stronger agreement between baseline (fresh) and successive freeze-thaw T2* values of tendon obtained with the UTE technique in comparison to T2 values obtained with a conventional clinical CPMG technique. Published by Elsevier Ireland Ltd.
引用
收藏
页码:349 / 353
页数:5
相关论文
共 28 条
[1]
[Anonymous], J ROY STAT SOC D STA, DOI DOI 10.2307/2987937
[2]
Ashwood-Smith M.J., 1980, Low temperature preservation in medicine and biology
[3]
Effects of freezing/thawing on the biomechanical properties of human tendons [J].
Clavert, P ;
Kempfl, JF ;
Bonnomet, F ;
Boutemy, P ;
Marcelin, L ;
Kahn, JL .
SURGICAL AND RADIOLOGIC ANATOMY, 2001, 23 (04) :259-262
[4]
Ultrashort echo time imaging with bicomponent analysis [J].
Du, Jiang ;
Diaz, Eric ;
Carl, Michael ;
Bae, Won ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) :645-649
[5]
Magic angle effect in magnetic resonance imaging of the Achilles tendon and enthesis [J].
Du, Jiang ;
Pak, Byung C. ;
Znamirowski, Richard ;
Statum, Sheronda ;
Takahashi, Atsushi ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IMAGING, 2009, 27 (04) :557-564
[6]
Quantitative Characterization of the Achilles Tendon in Cadaveric Specimens: T1 and T2*Measurements Using Ultrashort-TE MRI at 3 T [J].
Filho, Guinel H. ;
Du, Jiang ;
Pak, Byung C. ;
Statum, Sheronda ;
Znamorowski, Richard ;
Haghighi, Parviz ;
Bydder, Graeme ;
Chung, Christine B. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) :W117-W124
[7]
Optimal methods for the preservation of cartilage samples in MRI and correlative biochemical studies [J].
Fishbein, Kenneth W. ;
Canuto, Holly C. ;
Bajaj, Preeti ;
Camacho, Nancy Pleshko ;
Spencer, Richard G. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (05) :866-873
[8]
Fisher R. A., 1921, Metron, V1, P3
[9]
Effects of freezing on the biomechanical and structural properties of human posterior tibial tendons [J].
Giannini, Sandro ;
Buda, Roberto ;
Di Caprio, Francesco ;
Agati, Patrizia ;
Bigi, Adriana ;
De Pasquale, Viviana ;
Ruggeri, Alessandro .
INTERNATIONAL ORTHOPAEDICS, 2008, 32 (02) :145-151
[10]
Gold G, 2001, IN VIVO SHORT ECHO T, V9, P244