Effects of freezing on the biomechanical and structural properties of human posterior tibial tendons

被引:117
作者
Giannini, Sandro [1 ]
Buda, Roberto [1 ]
Di Caprio, Francesco [1 ]
Agati, Patrizia [2 ]
Bigi, Adriana [3 ]
De Pasquale, Viviana [4 ]
Ruggeri, Alessandro [4 ]
机构
[1] Univ Bologna, Rizzoli Orthopaed Inst, Orthopaed Clin, Bologna, Italy
[2] Univ Bologna, Dept Stat Sci, Bologna, Italy
[3] Univ Bologna, Dept Chem, Bologna, Italy
[4] Univ Bologna, Dept Human Anat, Bologna, Italy
关键词
D O I
10.1007/s00264-006-0297-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This work analyzes the effects of storage by fresh-freezing at -80 degrees C on the histological, structural and biomechanical properties of the human posterior tibial tendon (PTT), used for ACL reconstruction. Twenty-two PTTs were harvested from eleven donors. For each donor one tendon was frozen at -80 degrees C and thawed in physiological solution at 37 degrees C, and the other was tested without freezing (control). Transmission electron microscopy (TEM), differential scanning calorimetry (DSC) and biomechanical analysis were performed. We found the following mean changes in frozen-thawed tendons compared to controls: TEM showed an increase in the mean diameter of collagen fibrils and in fibril non-occupation mean ratio, while the mean number of fibrils decreased; DSC showed a decrease in mean denaturation temperature and denaturation enthalpy. Biomechanical analysis showed a decrease in ultimate load and ultimate stress, an increase in stiffness and a decrease in ultimate strain of tendons. In conclusion fresh-freezing brings about significant changes in the biomechanical and structural properties of the human PTT. A high variability exists in the biophysical properties of tendons among individuals and in the effects of storage on tendons. Therefore, when choosing an allograft tendon, particular care is needed to choose a biomechanically suitable graft.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 33 条
[1]
DETERMINATION OF THE RENATURATION LEVEL IN GELATIN FILMS [J].
ACHET, D ;
HE, XW .
POLYMER, 1995, 36 (04) :787-791
[2]
BARAD S, 1982, T ORTHOP RES SOC, V7, P378
[3]
Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction [J].
Caborn, DNM ;
Selby, JB .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (01) :102-105
[4]
Effects of freezing/thawing on the biomechanical properties of human tendons [J].
Clavert, P ;
Kempfl, JF ;
Bonnomet, F ;
Boutemy, P ;
Marcelin, L ;
Kahn, JL .
SURGICAL AND RADIOLOGIC ANATOMY, 2001, 23 (04) :259-262
[5]
A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts [J].
Donahue, TLH ;
Howell, SM ;
Hull, ML ;
Gregersen, C .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (06) :589-597
[6]
LOAD ELONGATION BEHAVIOR OF THE CANINE ANTERIOR CRUCIATE LIGAMENT [J].
DORLOT, JM ;
AITBASIDI, M ;
TREMBLAY, GM ;
DROUIN, G .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (03) :190-193
[7]
Biomechanics of anterior cruciate ligament reconstruction using twisted doubled hamstring tendons [J].
Ferretti, A ;
Conteduca, F ;
Morelli, F ;
Monteleone, L ;
Nanni, F ;
Valente, M .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :22-25
[8]
Gitelis Steven, 2002, Instr Course Lect, V51, P507
[9]
THE EFFECT OF INSITU FREEZING ON RABBIT PATELLAR TENDON - A HISTOLOGIC, BIOCHEMICAL, AND BIOMECHANICAL ANALYSIS [J].
GRAF, BK ;
FUJISAKI, K ;
VANDERBY, R ;
VAILAS, AC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (04) :401-405
[10]
Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: Biomechanical evaluation of the use of multiple strands and tensioning techniques [J].
Hamner, DL ;
Brown, CH ;
Steiner, ME ;
Hecker, AT ;
Hayes, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (04) :549-557