A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis

被引:95
作者
Schiefer, Matthew A. [1 ,2 ]
Triolo, Ronald J. [1 ,2 ,3 ]
Tyler, Dustin J. [1 ,2 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Vet Affairs Med Ctr, Louis Stokes Dept, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Orthopaed, Cleveland, OH 44106 USA
关键词
electrode; femoral nerve; flat interface nerve electrode (FINE); functional electrical stimulation (FES); selective stimulation;
D O I
10.1109/TNSRE.2008.918425
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Functional electrical stimulation (FES) can restore limb movements through electrically initiated, coordinated contractions of paralyzed muscles. The peripheral nerve is an attractive site for stimulation using cuff electrodes. Many applications will require the electrode to selectively activate many smaller populations of axons within a common nerve trunk. The purpose of this study is to computationally model the performance of a flat interface nerve electrode (FINE) on the proximal femoral nerve for standing and stepping applications. Simulations investigated, multiple FINE configurations to determine the optimal number and locations of contacts for the maximum muscular selectivity. Realistic finite element method (FEM) models were developed from digitized cross sections from cadaver femoral nerve specimens. Electrical potentials were calculated and interpolated voltages were applied to a double-cable axon model. Model output was analyzed to determine selectivity and estimate joint moments with a musculoskeletal model. Simulations indicated that a 22-contact FINE will produce the greatest selectivity. Simulations predicted that an eight-contact FINE can be expected to selectively stimulate each of the six muscles innervated by the proximal femoral nerve, producing a sufficient knee extension moment for the sit-to-stand transition and contributing 60% of the hip flexion moment needed during gait. We conclude that, whereas more contacts produce greater selectivity, eight channels are sufficient for standing and stepping with an FES system using a FINE on the common femoral nerve.
引用
收藏
页码:195 / 204
页数:10
相关论文
共 37 条
[1]  
BEHSE F, 1990, Acta Neurologica Scandinavica Supplementum, V82, P1
[2]   THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA [J].
BRAND, RA ;
PEDERSEN, DR ;
FRIEDERICH, JA .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :589-596
[3]   Sources and effects of electrode impedance during deep brain stimulation [J].
Butson, CR ;
Maks, CB ;
McIntyre, CC .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (02) :447-454
[4]   Selectivity of multiple-contact nerve cuff electrodes: A simulation analysis [J].
Choi, AQ ;
Cavanaugh, JK ;
Durand, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (02) :165-172
[5]  
Creasey G, 1996, J REHABIL RES DEV, V33, P123
[6]  
Delp S.L., 1990, SURG SIMULATION COMP
[7]   AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES [J].
DELP, SL ;
LOAN, JP ;
HOY, MG ;
ZAJAC, FE ;
TOPP, EL ;
ROSEN, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) :757-767
[8]  
Enoka RM, 2001, MUSCLE NERVE, V24, P4, DOI 10.1002/1097-4598(200101)24:1<4::AID-MUS13>3.0.CO
[9]  
2-F
[10]  
Ergas Z, 1985, Cent Nerv Syst Trauma, V2, P19