Coating of carbon fiber-reinforced polyetheretherketone implants with titanium to improve bone apposition

被引:103
作者
Devine, Declan M. [1 ]
Hahn, Joachim [1 ]
Richards, R. Geoffery [1 ,2 ]
Gruner, Heiko [3 ]
Wieling, Ronald [4 ]
Pearce, Simon G. [1 ]
机构
[1] AO Res Inst, Davos, Switzerland
[2] Cardiff Univ, Cardiff CF10 3AX, S Glam, Wales
[3] Medicoat AG, Magenwil, Switzerland
[4] Icotec AG, Altstatten, Swaziland
关键词
coating; orthopedic; PEEK; titanium; in vivo; PLASMA-SPRAYED TITANIUM; IN-VIVO; CALCIUM-PHOSPHATE; PEEK; ROUGHNESS; SURFACES; REMOVAL; VITRO;
D O I
10.1002/jbm.b.32861
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Carbon fiber-reinforced polyetheretherketone (CF/PEEK) is a thermoplastic composite biomaterial exhibiting properties suitable for load-bearing orthopedic implants. However, the hydrophobic surface of CF/PEEK implants induces the deposition of a peri-implant fibrous tissue capsule preventing bone apposition. However, if bone apposition was improved, the use of CF/PEEK in orthopedics could be increased as it has many advantages compared with metallic implants. In this study, CF/PEEK screws were coated with titanium (Ti) using two different techniques, namely vacuum plasma spraying (VPS) and physical vapor deposition (PVD) with uncoated screws as controls. These coatings were characterized and implanted in a loaded sheep tibia model. In the characterization of the screw surfaces using microscopy techniques, the uncoated screws were seen to have an irregular surface. The PVD coating appeared smooth and consistent, whereas the VPS coating appeared to be a rough coating with some inhomogeneities, which did not cover the entire surface area. Nevertheless, in the ex vivo analysis the VPS-coated screws had a screw removal torque which was statistically greater than uncoated and PVD-coated screws (p 0.002 for both comparisons). Additionally, the VPS-coated screws had a statistically higher bone contact area than the uncoated screws (p = 0.006), whereas no statistical difference was detected between VPS and PVD coating types (p = 0.11). Thereby illustrating that Ti coating of CF/PEEK screws significantly improve bone apposition and removal torque compared with uncoated CF/PEEK screws. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 25 条
[1]
In vivo comparison of the osseointegration of vacuum plasma sprayed titanium- and hydroxyapatite-coated implants [J].
Aebli, N ;
Krebs, J ;
Stich, H ;
Schawalder, P ;
Walton, M ;
Schwenke, D ;
Gruner, H ;
Gasser, B ;
Theis, JC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (02) :356-363
[2]
[Anonymous], INT J CARE INJURED
[3]
Physical characterization of different-roughness titanium surfaces, with and without hydroxyapatite coating, and their effect on human osteoblast-like cells [J].
Borsari, V ;
Giavaresi, G ;
Fini, M ;
Torricelli, P ;
Salito, A ;
Chiesa, R ;
Chiusoli, L ;
Volpert, A ;
Rimondini, L ;
Giardino, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) :359-368
[4]
Comparative in vitro study on a ultra-high roughness and dense titanium coating [J].
Borsari, V ;
Giavaresi, G ;
Fini, M ;
Torricelli, P ;
Tschon, M ;
Chiesa, R ;
Chiusoli, L ;
Salito, A ;
Volpert, A ;
Giardino, R .
BIOMATERIALS, 2005, 26 (24) :4948-4955
[5]
Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone [J].
Converse, Gabriel L. ;
Yue, Weimin ;
Roeder, Ryan K. .
BIOMATERIALS, 2007, 28 (06) :927-935
[6]
Gisep A, 2009, EUR CELLS MATER, V17, P10
[7]
GRUNER H, 2001, ENG MAT SER, P375
[8]
Surface activation of polyetheretherketone (PEEK) and formation of calcium phosphate coatings by precipitation [J].
Ha, SW ;
Kirch, M ;
Birchler, F ;
Eckert, KL ;
Mayer, J ;
Wintermantel, E ;
Sittig, C ;
PfundKlingenfuss, I ;
Textor, M ;
Spencer, ND ;
Guecheva, M ;
Vonmont, H .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (11) :683-690
[9]
NaOH treatment of vacuum-plasma-sprayed titanium on carbon fibre-reinforced poly(etheretherketone) [J].
Ha, SW ;
Eckert, KL ;
Wintermantel, E ;
Gruner, H ;
Guecheva, M ;
Vonmont, H .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (12) :881-886
[10]
The improvement of adhesive properties of PEEK through different pre-treatments [J].
Hallmann, Lubica ;
Mehl, Albert ;
Sereno, Nuno ;
Haemmerle, Christoph H. F. .
APPLIED SURFACE SCIENCE, 2012, 258 (18) :7213-7218