Microscopy study of intergranular stress corrosion cracking of X-52 line pipe steel

被引:31
作者
Li, J
Elboujdaini, M
Fang, B
Revie, RW
Phaneuf, MW
机构
[1] CANMET Mat Technol Lab, Ottawa, ON K1A 0G1, Canada
[2] Fib Inc, Ottawa, ON K1A 0G1, Canada
关键词
focused ion beam microscopy; intergranular cracking; pipeline steel; scanning electron microscopy; stress corrosion cracking; transmission electron microscopy; transgranular cracking;
D O I
10.5006/1.3280664
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Although the failure of X-52 linepipe steel due to stress corrosion cracking (SCC) remains a concern in the oil and gas industry, the mechanisms responsible for crack initiation and propagation are not well understood. In this work, SCC from a section of in-service X-52 linepipe steel was investigated. Features of intergranular cracks were characterized using optical microcopy, scanning electron microscopy (SEM), focused ion beam (FIB) microscopy. and transmission electron microscopy (TEM). The effect of carbide and phosphorus on crack propagation was emphasized.
引用
收藏
页码:316 / 322
页数:7
相关论文
共 28 条
[1]  
Anderson R.M., 2002, MICROSC MICROANAL, V8, P44
[2]  
ANIELSON MJ, 2001, CORROSION 2001
[3]  
EIBER RJ, 1996, MH295 NAT EN BOARD, P19
[4]  
FRESSLER RR, 1977, NACE 5 SCC HYDROGEN, P135
[5]   ELECTROCHEMICAL PROPERTIES OF FERRITE AND CEMENTITE IN RELATION TO STRESS CORROSION OF MILD STEELS IN NITRATE SOLUTIONS [J].
GREEN, JAS ;
PARKINS, RN .
CORROSION, 1968, 24 (03) :66-&
[6]   Hydrogen-facilitated anodic dissolution-type stress corrosion cracking of pipeline steels in near-neutral pH solution [J].
Gu, B ;
Luo, J ;
Mao, X .
CORROSION, 1999, 55 (01) :96-106
[7]  
KATZ DC, 2003, P 42 ANN C MET CIM, P293
[8]   Using fluctuation microscopy to characterize structural order in metallic glasses [J].
Li, J ;
Gu, X ;
Hufnagel, TC .
MICROSCOPY AND MICROANALYSIS, 2003, 9 (06) :509-515
[9]  
LI J, 2001, P MICR SOC CAN, V28, P26
[10]  
LI J, 2004, P COM AUG 3 7 2004, P515