Morphometric Assessment of Coronary Stenosis Relevance With Optical Coherence Tomography A Comparison With Fractional Flow Reserve and Intravascular Ultrasound

被引:139
作者
Gonzalo, Nieve [1 ]
Escaned, Javier [1 ]
Alfonso, Fernando [1 ]
Nolte, Christian [1 ]
Rodriguez, Vera [1 ]
Jimenez-Quevedo, Pilar [1 ]
Banuelos, Camino [1 ]
Fernandez-Ortiz, Antonia [1 ]
Garcia, Eulogio [1 ]
Hernandez-Antolin, Rosana [1 ]
Macaya, Carlos [1 ]
机构
[1] Hosp Clin San Carlos, Dept Intervent Cardiol, Cardiovasc Inst, Madrid 28040, Spain
关键词
fractional flow reserve; functional assessment; intermediate coronary stenosis; intravascular ultrasound; optical coherence tomography; ARTERY STENOSES; FUNCTIONAL SEVERITY; FOLLOW-UP; VIVO; REPRODUCIBILITY; ANGIOGRAPHY;
D O I
10.1016/j.jacc.2011.09.078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The study sought to assess the diagnostic efficiency of optical coherence tomography (OCT) in identifying hemodynamically severe coronary stenoses as determined by fractional flow reserve (FFR). Concomitant OCT and intravascular ultrasound (IVUS) area measurements were performed in a subgroup of patients to compare the diagnostic efficiency of both techniques. Background The value of OCT to determine stenosis severity remains unsettled. Methods Sixty-one stenoses with intermediate angiographic severity were studied in 56 patients. Stenoses were labeled as severe if FFR <= 0.80. OCT interrogation was performed in all cases, with concomitant IVUS imaging in 47 cases. Results Angiographic stenosis severity was 50.9 +/- 8% diameter stenosis with 1.28 +/- 0.3 mm minimal lumen diameter. FFR was <= 0.80 in 28 (45.9%) stenoses. An overall moderate diagnostic efficiency of OCT was found (area under the curve [AUC]: 0.74; 95% confidence interval [CI]: 0.61 to 0.84), with sensitivity/specificity of 82%/63% associated with an optimal cutoff value of 1.95 mm(2). Comparison of the results in patients with simultaneous IVUS and OCT imaging revealed no significant differences in the diagnostic efficiency of OCT (AUC: 0.70; 95% CI: 0.55 to 0.83) and IVUS (AUC. 0.63; 95% CI: 0.47 to 0.77; p = 0.19). Sensitivity/specificity for IVUS was 67%/65% for an optimal cutoff value of 2.36 mm(2). In the subgroup of small vessels (reference diameter <3 mm) OCT showed a significantly better diagnostic efficiency (AUC: 0.77; 95% CI: 0.60 to 0.89) than IVUS (AUC: 0.63; 95% CI: 0.46 to 0.78) to identify functionally significant stenoses (p = 0.04). Conclusions OCT has a moderate diagnostic efficiency in identifying hemodynamically severe coronary stenoses. Although OCT seems slightly superior to IVUS for this purpose (particularly in vessels <3 mm), its low specificity precludes its use as a substitute of FFR for functional stenosis assessment. (J Am Coll Cardiol 2012;59:1080-9) (C) 2012 by the American College of Cardiology Foundation
引用
收藏
页码:1080 / 1089
页数:10
相关论文
共 23 条
[1]   Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions [J].
Abizaid, AS ;
Mintz, GS ;
Mehran, R ;
Abizaid, A ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Wu, HS ;
Pappas, C ;
Kent, KM ;
Leon, MB .
CIRCULATION, 1999, 100 (03) :256-261
[2]   Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional glow reserve [J].
Briguori, C ;
Anzuini, A ;
Airoldi, F ;
Gimelli, G ;
Nishida, T ;
Adamian, M ;
Corvaja, N ;
Di Mario, C ;
Colombo, A .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :136-141
[3]   Anatomical and physiologic assessments in patients with small coronary artery disease: Final results of the Physiologic and Anatomical Evaluation Prior to and After Stent Implantation in Small Coronary Vessels (PHANTOM) trial [J].
Costa, Marco A. ;
Sabate, Manel ;
Staico, Rodolfo ;
Alfonso, Fernando ;
Seixas, Ana C. ;
Albertal, Mariano ;
Crossman, Arthur ;
Angiolillo, Dominick J. ;
Zenni, Martin ;
Sousa, J. Eduardo ;
Macaya, Carlos ;
Bass, Theodore A. .
AMERICAN HEART JOURNAL, 2007, 153 (02) :296.e1-296.e7
[4]   Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach [J].
Gonzalo, N. ;
Serruys, P. W. ;
Okamura, T. ;
Shen, Z. J. ;
Onuma, Y. ;
Garcia-Garcia, H. M. ;
Sarno, G. ;
Schultz, C. ;
van Geuns, R. J. ;
Ligthart, J. ;
Regar, E. .
HEART, 2009, 95 (23) :1913-1919
[5]  
Gonzalo N, 2008, Minerva Cardioangiol, V56, P511
[6]   Second-Generation Optical Coherence Tomography in Clinical Practice. High-Speed Data Acquisition Is Highly Reproducible in Patients Undergoing Percutaneous Coronary Intervention [J].
Gonzalo, Nieves ;
Tearney, Guillermo J. ;
Serruys, Patrick W. ;
van Soest, Gijs ;
Okamura, Takayuki ;
Garcia-Garcia, Hector M. ;
Jan van Geuns, Robert ;
van der Ent, Martin ;
Ligthart, Jurgen ;
Bouma, Brett E. ;
Regar, Evelyn .
REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (08) :893-903
[7]   Reproducibility of quantitative optical coherence tomography for stent analysis [J].
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Serruys, Patrick W. ;
Commissaris, Koen H. ;
Bezerra, Hiram ;
Gobbens, Pierre ;
Costa, Marco ;
Regar, Evelyn .
EUROINTERVENTION, 2009, 5 (02) :224-232
[8]   Quantitative Ex Vivo and In Vivo Comparison of Lumen Dimensions Measured by Optical Coherence Tomography and Intravascular Ultrasound in Human Coronary Arteries [J].
Gonzalo, Nieves ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
van Soest, Gijs ;
Okamura, Takayuki ;
Ligthart, Jurgen ;
Knaapen, Michiel ;
Verheye, Stefan ;
Bruining, Nico ;
Regar, Evelyn .
REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (06) :615-624
[9]   In Vivo Assessment of High-Risk Coronary Plaques at Bifurcations With Combined Intravascular Ultrasound and Optical Coherence Tomography [J].
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Regar, Evelyn ;
Barlis, Peter ;
Wentzel, Jolanda ;
Onuma, Yoshinobu ;
Ligthart, Jurgen ;
Serruys, Patrick W. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (04) :473-482
[10]   Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents [J].
Guagliumi, Giulio ;
Musumeci, Giuseppe ;
Sirbu, Vasile ;
Bezerra, Hiram G. ;
Suzuki, Nobuaki ;
Fiocca, Luigi ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Trivisonno, Antonio ;
Valsecchi, Orazio ;
Biondi-Zoccai, Giuseppe ;
Costa, Marco A. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (05) :531-539