Reproducibility of quantitative optical coherence tomography for stent analysis

被引:91
作者
Gonzalo, Nieves [1 ]
Garcia-Garcia, Hector M. [1 ]
Serruys, Patrick W. [1 ]
Commissaris, Koen H. [2 ]
Bezerra, Hiram [3 ,4 ]
Gobbens, Pierre [2 ]
Costa, Marco [3 ,4 ]
Regar, Evelyn [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Cardialysis BV, Rotterdam, Netherlands
[3] Cardialysis Cleveland Core Lab, Cleveland, OH USA
[4] Univ Hosp Cleveland, Case Med Ctr, Cleveland, OH 44106 USA
关键词
Optical coherence tomography; stent analysis; reproducibility;
D O I
10.4244/EIJV5I2A35
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To assess the inter-and intra-observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with optical coherence tomography (OCT). Methods and results: Ten drug-eluting stents (244 frames, 1712 struts) imaged with OCT nine months after implantation were analysed by two independent analysts. One of the analysts repeated the analysis of five stents (120 frames, 795 struts) one week later. Offline analysis was performed with the proprietary LightLab Imaging software. The number of struts was counted and lumen and stent area contours were traced. Tissue coverage thickness was measured at 360 degrees of vessel circumference and in front of every individual strut. The number of malapposed struts was determined. There was good agreement for strut number count (Kendall's Tau-b 0.90 for inter-and 0.94 for intra- observer variability). The relative difference for lumen area, stent area and tissue coverage measurements was around 1%. There was complete inter-and intra-observer agreement for malapposed struts classification (4 out of 1708 struts, Kappa=1). Conclusions: In a Corelab setting, the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with OCT is excellent. This emphasises the value of OCT as a tool for the clinical long-term assessment of stents.
引用
收藏
页码:224 / 232
页数:9
相关论文
共 19 条
[1]   Intravascular ultrasound findings during episodes of drug-eluting Stent thrombosis [J].
Alfonso, Fernando ;
Suarez, Alfonso ;
Perez-Vizcayno, Maria J. ;
Moreno, Raul ;
Escaned, Javier ;
Banuelos, Camino ;
Jimenez, Pilar ;
Bernardo, Esther ;
Angiolillo, Dominick J. ;
Hernandez, Rosana ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (21) :2095-2097
[2]   Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation - Insights from serial intravascular ultrasound analysis in the TAXUS II study [J].
Aoki, J ;
Colombo, A ;
Dudek, D ;
Banning, AP ;
Drzewiecki, J ;
Zmudka, K ;
Schiele, F ;
Russell, ME ;
Koglin, J ;
Serruys, PW .
CIRCULATION, 2005, 112 (25) :3876-3883
[3]   An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets [J].
Bonnema, Garret T. ;
Cardinal, Kristen O'Halloran ;
Williams, Stuart K. ;
Barton, Jennifer K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (12) :3083-3098
[4]   Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography [J].
Chen, B. X. ;
Ma, F. Y. ;
Luo, W. ;
Ruan, J. H. ;
Xie, W. L. ;
Zhao, X. Z. ;
Sun, S. H. ;
Guo, X. M. ;
Wang, F. ;
Tian, T. ;
Chu, X. W. .
HEART, 2008, 94 (05) :566-570
[5]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[6]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[7]  
Gonzalo N, 2008, Minerva Cardioangiol, V56, P511
[8]   Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk [J].
Joner, Michael ;
Finn, Aloke V. ;
Farb, Andrew ;
Mont, Erik K. ;
Kolodgie, Frank D. ;
Ladich, Elena ;
Kutys, Robert ;
Skorija, Kristi ;
Gold, Herman K. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :193-202
[9]   Comparison of Vascular Response After Sirolimus-Eluting Stent Implantation Between Patients With Unstable and Stable Angina Pectoris [J].
Kubo, Takashi ;
Imanishi, Toshio ;
Kitabata, Hironori ;
Kuroi, Akio ;
Ueno, Satoshi ;
Yamano, Takashi ;
Tanimoto, Takashi ;
Matsuo, Yoshiki ;
Masho, Takashi ;
Takarada, Shigeho ;
Tanaka, Atsushi ;
Nakamura, Nobuo ;
Mizukoshi, Masato ;
Tomobuchi, Yoshiaki ;
Akasaka, Takashi .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (04) :475-484
[10]   Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography [J].
Matsumoto, Daisuke ;
Shite, Junya ;
Shinke, Toshiro ;
Otake, Hiromasa ;
Tanino, Yusuke ;
Ogasawara, Daisuke ;
Sawada, Takahiro ;
Paredes, Oscar Luis ;
Hirata, Ken-ichi ;
Yokoyama, Mitsuhiro .
EUROPEAN HEART JOURNAL, 2007, 28 (08) :961-967