Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation

被引:674
作者
Cook, Stephane [1 ]
Wenaweser, Peter [1 ]
Togni, Mario [1 ]
Billinger, Michael [1 ]
Morger, Cyrill [1 ]
Seiler, Christian [1 ]
Vogel, Rolf [1 ]
Hess, Otto [1 ]
Meier, Bernhard [1 ]
Windecker, Stephan [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
关键词
coronary disease; imaging; patients; stents; ultrasonics;
D O I
10.1161/CIRCULATIONAHA.106.658237
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. Methods and Results - Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for >= 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630 +/- 166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9 +/- 16.0 versus 13.3 +/- 7.9 mm; P < 0.001) and stents (34.6 +/- 22.4 versus 18.6 +/- 9.5 mm; P < 0.001), more stents per lesion (1.6 +/- 0.9 versus 1.1 +/- 0.4; P < 0.001), and stent overlap (39% versus 8%; P < 0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9 +/- 6.9 versus 20.4 +/- 7.2 mm(2); P=0.46) but significantly larger for the in-stent segment (28.6 +/- 11.9 versus 20.1 +/- 6.7 mm(2); P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P < 0.001) and maximal incomplete stent apposition area was larger (8.3 +/- 7.5 versus 4.0 +/- 3.8 mm(2); P=0.03) in patients with very late stent thrombosis compared with controls. Conclusions - Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.
引用
收藏
页码:2426 / 2434
页数:9
相关论文
共 25 条
  • [1] Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis
    Ako, J
    Morino, Y
    Honda, Y
    Hassan, A
    Sonoda, S
    Yock, PG
    Leon, MB
    Moses, JW
    Bonneau, HN
    Fitzgerald, PJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) : 1002 - 1005
  • [2] Predictors of subacute stent thrombosis - Results of a systematic intravascular ultrasound study
    Cheneau, E
    Leborgne, L
    Mintz, GS
    Kotani, J
    Pichard, AD
    Satler, LF
    Canos, D
    Castagna, M
    Weissman, NJ
    Waksman, R
    [J]. CIRCULATION, 2003, 108 (01) : 43 - 47
  • [3] Very late thrombosis after drug-eluting stents
    Feres, Fausto
    Costa, J. Ribamar, Jr.
    Abizaid, Alexandre
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (01) : 83 - 88
  • [4] Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting Stent implantation
    Fujii, K
    Carlier, SG
    Mintz, GS
    Yang, YM
    Moussa, I
    Weisz, G
    Dangas, G
    Mehran, R
    Lansky, AJ
    Kreps, EM
    Collins, M
    Stone, GW
    Lansky, AJ
    Kreps, EM
    Collins, M
    Stone, GW
    Moses, JW
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) : 995 - 998
  • [5] Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up
    Hong, MK
    Mintz, GS
    Lee, CW
    Park, DW
    Park, KM
    Lee, BK
    Kim, YH
    Song, JM
    Han, KH
    Kang, DH
    Cheong, SS
    Song, JK
    Kim, JJ
    Park, SW
    Park, SJ
    [J]. CIRCULATION, 2006, 113 (03) : 414 - 419
  • [6] Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation
    Hong, MK
    Mintz, GS
    Lee, CW
    Kim, YH
    Lee, SW
    Song, JM
    Han, KH
    Kang, DH
    Song, JK
    Kim, JJ
    Park, SW
    Park, SJ
    [J]. CIRCULATION, 2004, 109 (07) : 881 - 886
  • [7] Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents
    Iakovou, I
    Schmidt, T
    Bonizzoni, E
    Ge, L
    Sangiorgi, GM
    Stankovic, G
    Airoldi, F
    Chieffo, A
    Montorfano, M
    Carlino, M
    Michev, I
    Corvaja, N
    Briguori, C
    Gerckens, U
    Grube, E
    Colombo, A
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17): : 2126 - 2130
  • [8] Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk
    Joner, Michael
    Finn, Aloke V.
    Farb, Andrew
    Mont, Erik K.
    Kolodgie, Frank D.
    Ladich, Elena
    Kutys, Robert
    Skorija, Kristi
    Gold, Herman K.
    Virmani, Renu
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) : 193 - 202
  • [9] Kozuma K, 1999, J INVASIVE CARDIOL, V11, P651
  • [10] Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus- and paclitaxel-eluting stents
    Kuchulakanti, PK
    Chu, WW
    Torguson, R
    Ohlmann, P
    Rha, SW
    Clavijo, LC
    Kim, SW
    Bui, A
    Gevorkian, N
    Xue, ZY
    Smith, K
    Fournadjieva, J
    Suddath, WO
    Satler, LF
    Pichard, AD
    Kent, KM
    Waksman, R
    [J]. CIRCULATION, 2006, 113 (08) : 1108 - 1113