Reproducibility of quantitative optical coherence tomography for stent analysis

被引:91
作者
Gonzalo, Nieves [1 ]
Garcia-Garcia, Hector M. [1 ]
Serruys, Patrick W. [1 ]
Commissaris, Koen H. [2 ]
Bezerra, Hiram [3 ,4 ]
Gobbens, Pierre [2 ]
Costa, Marco [3 ,4 ]
Regar, Evelyn [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Cardialysis BV, Rotterdam, Netherlands
[3] Cardialysis Cleveland Core Lab, Cleveland, OH USA
[4] Univ Hosp Cleveland, Case Med Ctr, Cleveland, OH 44106 USA
关键词
Optical coherence tomography; stent analysis; reproducibility;
D O I
10.4244/EIJV5I2A35
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To assess the inter-and intra-observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with optical coherence tomography (OCT). Methods and results: Ten drug-eluting stents (244 frames, 1712 struts) imaged with OCT nine months after implantation were analysed by two independent analysts. One of the analysts repeated the analysis of five stents (120 frames, 795 struts) one week later. Offline analysis was performed with the proprietary LightLab Imaging software. The number of struts was counted and lumen and stent area contours were traced. Tissue coverage thickness was measured at 360 degrees of vessel circumference and in front of every individual strut. The number of malapposed struts was determined. There was good agreement for strut number count (Kendall's Tau-b 0.90 for inter-and 0.94 for intra- observer variability). The relative difference for lumen area, stent area and tissue coverage measurements was around 1%. There was complete inter-and intra-observer agreement for malapposed struts classification (4 out of 1708 struts, Kappa=1). Conclusions: In a Corelab setting, the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with OCT is excellent. This emphasises the value of OCT as a tool for the clinical long-term assessment of stents.
引用
收藏
页码:224 / 232
页数:9
相关论文
共 19 条
[11]   Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, in a rabbit carotid model [J].
Prati, F. ;
Zimarino, M. ;
Stabile, E. ;
Pizzicannella, G. ;
Fouad, T. ;
Rabozzi, R. ;
Filippini, A. ;
Pizzicannella, J. ;
Cera, M. ;
De Caterina, R. .
HEART, 2008, 94 (02) :217-221
[12]   Reproducibility of neointima quantification with motorized intravascular ultrasound pullback in stented coronary arteries [J].
Regar, E ;
Werner, F ;
Siebert, U ;
Rieber, J ;
Theisen, K ;
Mudra, H ;
Klauss, V .
AMERICAN HEART JOURNAL, 2000, 139 (04) :632-637
[13]  
Regar Evelyn., 2007, Optical coherence tomography in cardiovascular research
[14]   In Vivo Comparison Between Optical Coherence Tomography and Intravascular Ultrasound for Detecting Small Degrees of In-Stent Neointima After Stent Implantation [J].
Suzuki, Yoriyasu ;
Ikeno, Fumiaki ;
Koizumi, Tomomi ;
Tio, Fermin ;
Yeung, Alan C. ;
Yock, Paul G. ;
Fitzgerald, Peter J. ;
Fearon, William F. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (02) :168-173
[15]   Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography - Do uncovered struts persist? [J].
Takano, Masamichi ;
Yamamoto, Masanori ;
Inami, Shigenobu ;
Murakami, Daisuke ;
Seimiya, Koji ;
Ohba, Takayoshi ;
Seino, Yoshihiko ;
Mizuno, Kyoichi .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (09) :968-969
[16]   A novel approach for quantitative analysis of intracoronary optical coherence tomography: High inter-observer agreement with computer-assisted contour detection [J].
Tanimoto, Shuzou ;
Rodriguez-Granillo, Gaston ;
Barlis, Peter ;
de Winter, Sebastiaan ;
Bruining, Nico ;
Hamers, Ronald ;
Knappen, Michiel ;
Verheye, Stefan ;
Serruys, Patrick W. ;
Regar, Evelyn .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :228-235
[17]  
Tsuchida Keiichi, 2007, EuroIntervention, V3, P100
[18]   Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation [J].
Xie, Yong ;
Takano, Masamichi ;
Murakami, Daisuke ;
Yamamoto, Masanori ;
Okamatsu, Kentaro ;
Inami, Shigenobu ;
Seimiya, Koji ;
Ohba, Takayoshi ;
Seino, Yoshihiko ;
Mizuno, Kyoichi .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (01) :27-31
[19]   Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: evaluation by optical coherence tomography [J].
Yao Zhu-hua ;
Matsubara, Tetsuo ;
Inada, Tsuyoshi ;
Suzuki, Yasuyoshi ;
Suzuki, Takahiko .
CHINESE MEDICAL JOURNAL, 2008, 121 (06) :503-507