Reproducibility of neointima quantification with motorized intravascular ultrasound pullback in stented coronary arteries

被引:16
作者
Regar, E
Werner, F
Siebert, U
Rieber, J
Theisen, K
Mudra, H
Klauss, V
机构
[1] Klinikum Innenstadt, Med Klin, D-80336 Munich, Germany
[2] Univ Munich, Inst Med Informat Biometrie & Epidemiol, Munich, Germany
关键词
D O I
10.1016/S0002-8703(00)90040-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Intravascular ultrasound (IVUS) imaging has shown excellent reproducibility immediately after coronary stent implantation. However, the variability of measurements in lesions late after stent implantation, when neointima formation is present, has not been studied. Neointimal tissue is generally tow echogenic and thus difficult to quantify. We therefore sought to analyze the reproducibility of morphometric measurements late after stent implantation. Methods and Results Fifty consecutive patients were investigated 6 months after Patmaz-Schatz stent implantation (motorized catheter pullback 0.5 mm/s). Two experienced investigators independently identified the stent area, lumen area, and neointimal area at different sites within the stent. Planimetric measurements were performed with commercially available software. Correlation coefficient and mean difference for corresponding measurements were calculated for the intraobserver and interobserver comparisons. Variability for the intraobserver and interobserver comparisons was similar. Observer agreement regarding the presence of neointimal hyperplasia was as high as 71% (interobserver comparison 62%). The mean difference for neointima area was 0.06 +/- 1.5 mm(2) (-0.6 +/- 1.5 mm(2)); mean differences for lumen area were 0.02 +/- 0.1.9 mm(2) (0.03 +/- 0.17 mm(2)) and for stent area 0.01 +/- 0.09 mm(2) (-0.02 +/- 0.12 mm(2)) (values for interobserver comparison are given in parentheses), Correlation between measurements was high for all structures: correlation coefficients were 0.66 (0.69) for neointima, 0.94 (0.95) for lumen, and 0.95 (0.91) for stent area. Conclusions Morphometric measurements of IVUS investigations with motorized IVUS pullback late after stent placement show good reproducibility, Intraobserver variability and interobserver variability are low. Differences for corresponding measurements were more pronounced for neointima area. Motorized catheter pullback guarantees high reliability of IVUS measurements and should be used routinely for clinical IVUS studies.
引用
收藏
页码:632 / 637
页数:6
相关论文
共 23 条
[1]  
ANDERSON PG, 1992, J AM COLL CARDIOL, V19, P272
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[4]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[5]   SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS [J].
DUSSAILLANT, GR ;
MINTZ, GS ;
PICHARD, AD ;
KENT, KM ;
SATLER, LF ;
POPMA, JJ ;
WONG, SC ;
LEON, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) :720-724
[6]   Pathology of acute and chronic coronary stenting in humans [J].
Farb, A ;
Sangiorgi, G ;
Carter, AJ ;
Walley, VM ;
Edwards, WD ;
Schwartz, RS ;
Virmani, R .
CIRCULATION, 1999, 99 (01) :44-52
[7]   PRELIMINARY EXPERIENCE WITH INTRAVASCULAR ULTRASOUND-GUIDED PALMAZ-SCHATZ CORONARY STENTING - THE ACUTE AND SHORT-TERM RESULTS ON A CONSECUTIVE SERIES OF PATIENTS [J].
HALL, P ;
COLOMBO, A ;
ALMAGOR, Y ;
MAIELLO, L ;
NAKAMURA, S ;
MARTINI, G ;
TOBIS, JM .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1994, 7 (02) :141-159
[8]   INTRACORONARY ULTRASOUND IMAGING - INTRAOBSERVER AND INTEROBSERVER VARIABILITY OF MORPHOMETRIC MEASUREMENTS [J].
HAUSMANN, D ;
LUNDKVIST, AJS ;
FRIEDRICH, GJ ;
MULLEN, WL ;
FITZGERALD, PJ ;
YOCK, PG .
AMERICAN HEART JOURNAL, 1994, 128 (04) :674-680
[9]   Impact of target lesion calcification on coronary stent expansion after rotational atherectomy [J].
Henneke, KH ;
Regar, E ;
König, A ;
Werner, F ;
Klauss, V ;
Metz, J ;
Theisen, K ;
Mudra, H .
AMERICAN HEART JOURNAL, 1999, 137 (01) :93-99
[10]  
Hiro T, 1996, Am J Card Imaging, V10, P219