A high-intensity US probe designed for intraductal tumor destruction:: experimental results

被引:19
作者
Prat, F
Lafon, C
Margonari, J
Gorry, F
Theillère, Y
Chapelon, JY
Cathignol, D
机构
[1] CHU Bicetre, Serv Malad Foie & Appareil Digest, F-94275 Le Kremlin Bicetre, France
[2] INSERM, F-69008 Lyon, France
基金
澳大利亚研究理事会;
关键词
D O I
10.1053/ge.1999.v50.98451
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Many digestive tract tumors spread inside the lumen and are not amenable to curative surgical treatment. An intraluminal method of tumor destruction would be useful for palliative or even curative purposes. High-intensity ultrasound (US) is suitable for such purposes. Our objective was to perform experiments with animal models that would lead to development of a high-intensity US probe for intraductal tumor destruction suitable for insertion through a large-channel endoscope. Methods: The active part of the high-intensity US applicator consisted of a water-cooled piezoceramic plane transducer (3 x 10 mm) operating at 5 MHz for deep or 10 MHz for shallow tissue penetration. A cylinder of tissue was destroyed by means of rotating the transducer on its axis through a flexible shaft, Experiments were conducted in vitro on livers of butchered pigs (10 lesions), in vivo on exteriorized pig livers (15 lesions), and on metastatic Dunning tumors (AT(2) subline) implanted subcutaneously in 28 rats (treated n = 16, controls n = 12). Results: In experiments on pig livers, high-intensity US induced highly reproducible cylinders of coagulation necrosis (diameter 20 +/- 1 mm, height 8 +/- 1 mm) with sharply demarcated and serrated boundaries. The exposure duration to achieve such lesions was 5 minutes. Regions of coagulation necrosis obtained in vivo were similar in size and shape. AII 12 control rats died or were killed because of diffuse cancer by day 15 after implantation; 64% of the treated rats were tumor free 30 days after treatment, and 36% had local recurrences. Conclusion: This high-intensity US probe induces highly reproducible cylinders of coagulation necrosis and is effective against tumors in animals.
引用
收藏
页码:388 / 392
页数:5
相关论文
共 11 条
  • [1] CHAPELON JY, 1992, CANCER RES, V52, P6353
  • [2] EFFECT OF BLOOD PERFUSION ON THE ABLATION OF LIVER PARENCHYMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    CHEN, L
    TERHAAR, G
    HILL, CR
    DWORKIN, M
    CARNOCHAN, P
    YOUNG, H
    BENSTED, JPM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (11) : 1661 - 1673
  • [3] FRY F J, 1978, Ultrasound in Medicine and Biology, V4, P337, DOI 10.1016/0301-5629(78)90022-4
  • [4] Gelet A, 1996, EUR UROL, V29, P174
  • [5] Design and in vitro results of a high intensity ultrasound interstitial applicator
    Lafon, C
    Chapelon, JY
    Prat, F
    Gorry, F
    Theillere, Y
    Cathignol, D
    [J]. ULTRASONICS, 1998, 36 (1-5) : 683 - 687
  • [6] Design and preliminary results of an ultrasound applicator for interstitial thermal coagulation
    Lafon, C
    Chapelon, JY
    Prat, F
    Gorry, F
    Margonari, J
    Theillere, Y
    Cathignol, D
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (01) : 113 - 122
  • [7] High-intensity focused ultrasound transducers suitable for endoscopy: feasibility study in rabbits
    Prat, F
    Chapelon, JY
    Arefiev, A
    Cathignol, D
    Souchon, R
    Theilliere, Y
    [J]. GASTROINTESTINAL ENDOSCOPY, 1997, 46 (04) : 348 - 351
  • [8] CHARACTERIZATION OF EXTRACORPOREAL ABLATION OF NORMAL AND TUMOR-BEARING LIVER-TISSUE BY HIGH-INTENSITY FOCUSED ULTRASOUND
    SIBILLE, A
    PRAT, F
    CHAPELON, JY
    ABOUELFADIL, F
    HENRY, L
    THEILLIERE, Y
    PONCHON, T
    CATHIGNOL, D
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) : 803 - 813
  • [9] Stauffer P. R., 1995, THERMORADIOTHERAPY T, P279, DOI 10.1007/978-3-642-57858-8_13
  • [10] ULTRASOUND FOCAL BEAM SURGERY
    TERHAAR, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) : 1089 - 1100