Commercial Nucleic-Acid Amplification Tests for Diagnosis of Pulmonary Tuberculosis in Respiratory Specimens: Meta-Analysis and Meta-Regression

被引:149
作者
Ling, Daphne I. [2 ]
Flores, Laura L. [3 ]
Riley, Lee W. [2 ,4 ]
Pai, Madhukar [1 ]
机构
[1] McGill Univ, Dept Epidemiol Biostat & Occupat Hlth, Montreal, PQ, Canada
[2] Univ Calif Berkeley, Sch Publ Hlth, Div Epidemiol, Berkeley, CA USA
[3] San Francisco Gen Hosp, Div Pulmonary & Critical Care Med, San Francisco, CA USA
[4] Univ Calif Berkeley, Sch Publ Hlth, Div Infect Dis, Berkeley, CA USA
来源
PLOS ONE | 2008年 / 3卷 / 02期
关键词
D O I
10.1371/journal.pone.0001536
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background. Hundreds of studies have evaluated the diagnostic accuracy of nucleic-acid amplification tests (NAATs) for tuberculosis (TB). Commercial tests have been shown to give more consistent results than in-house assays. Previous meta-analyses have found high specificity but low and highly variable estimates of sensitivity. However, reasons for variability in study results have not been adequately explored. We performed a meta-analysis on the accuracy of commercial NAATs to diagnose pulmonary TB and meta-regression to identify factors that are associated with higher accuracy. Methodology/Principal Findings. We identified 2948 citations from searching the literature. We found 402 articles that met our eligibility criteria. In the final analysis, 125 separate studies from 105 articles that reported NAAT results from respiratory specimens were included. The pooled sensitivity was 0.85 (range 0.36-1.00) and the pooled specificity was 0.97 (range 0.54-1.00). However, both measures were significantly heterogeneous (p<.001). We performed subgroup and meta-regression analyses to identify sources of heterogeneity. Even after stratifying by type of commercial test, we could not account for the variability. In the meta-regression, the threshold effect was significant (p=.01) and the use of other respiratory specimens besides sputum was associated with higher accuracy. Conclusions/Significance. The sensitivity and specificity estimates for commercial NAATs in respiratory specimens were highly variable, with sensitivity lower and more inconsistent than specificity. Thus, summary measures of diagnostic accuracy are not clinically meaningful. The use of different cut-off values and the use of specimens other than sputum could explain some of the observed heterogeneity. Based on these observations, commercial NAATs alone cannot be recommended to replace conventional tests for diagnosing pulmonary TB. Improvements in diagnostic accuracy, particularly sensitivity, need to be made in order for this expensive technology to be worthwhile and beneficial in low-resource countries.
引用
收藏
页数:11
相关论文
共 147 条
  • [1] DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN CLINICAL SPECIMENS BY POLYMERASE CHAIN-REACTION AND GEN-PROBE AMPLIFIED MYCOBACTERIUM-TUBERCULOSIS DIRECT TEST
    ABE, C
    HIRANO, K
    WADA, M
    KAZUMI, Y
    TAKAHASHI, M
    FUKASAWA, Y
    YOSHIMURA, T
    MIYAGI, C
    GOTO, S
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (12) : 3270 - 3274
  • [2] Abu-Amero Khaled Khader, 2002, Molecular Biology Today, V3, P39
  • [3] Al Zahrani K, 2001, INT J TUBERC LUNG D, V5, P855
  • [4] Evaluation of the Upgraded Amplified Mycobacterium Tuberculosis Direct Test (Gen-Probe) for direct detection of Mycobacterium tuberculosis in respiratory and non-respiratory specimens
    Alcalá, L
    Ruiz-Serrano, MJ
    Hernangómez, S
    Marín, M
    Garcia de Viedma, D
    San Juan, R
    Bouza, E
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2001, 41 (1-2) : 51 - 56
  • [5] Clinical evaluation of the Amplified Mycobacterium Tuberculosis Direct 2 test (AMTD-2, GenProbe) for rapid diagnosis of tuberculosis
    Artiles, F
    Pena, MJ
    Campos-Herrero, MI
    Lafarga, B
    [J]. ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2001, 19 (02): : 53 - 56
  • [6] Evaluation of the semiautomated Abbott LCx Mycobacterium tuberculosis assay for direct detection of Mycobacterium tuberculosis in respiratory specimens
    Ausina, V
    Gamboa, F
    Gazapo, E
    Manterola, JM
    Lonca, J
    Matas, L
    Manzano, JR
    Rodrigo, C
    Cardona, PJ
    Padilla, E
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (08) : 1996 - 2002
  • [7] An evaluation of the BD ProbeTec ET system for the direct detection of Mycobacterium tuberculosis in respiratory samples
    Barrett, A
    Magee, JG
    Freeman, R
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2002, 51 (10) : 895 - 898
  • [8] Detection of Mycobacterium tuberculosis in sputum from Surui Indian subjects, Brazilian Amazon
    Basta, Paulo Cesar
    Oelemann, Maranibia A. C.
    Oelemann, Walter M. R.
    Fonseca, Leila de Souza
    Coimbra, Carlos E. A., Jr.
    [J]. MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2006, 101 (06): : 581 - 584
  • [9] EVALUATION OF AMPLICOR PCM FOR DIRECT-DETECTION OF MYCOBACTERIUM-TUBERCULOSIS FROM SPUTUM SPECIMENS
    BEAVIS, KG
    LICHTY, MB
    JUNGKIND, DL
    GIGER, O
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (10) : 2582 - 2586
  • [10] Utility of PCR in diagnosing pulmonary tuberculosis
    Bennedsen, J
    Thomsen, VO
    Pfyffer, GE
    Funke, G
    Feldmann, K
    Beneke, A
    Jenkins, PA
    Hegginbothom, M
    Fahr, A
    Hengstler, M
    Cleator, G
    Klapper, P
    Wilkins, EGL
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (06) : 1407 - 1411